5.  Connecting a hose 

 
5.1. The connection point for the drain hose is located on the right-hand side of the condensation tank (see diagram 

below). First remove the black sealing plug there. 

5.2. It is best to use a ½ inch plastic hose and pass it through the hole provided on the side (alternatively the lower 

hole) and then put the hose over the plastic tap provided for this purpose.  

5.3. Make sure that it fits properly. For safety, we recommend fixing the hose with a clamp/clip ! 
5.4. Make sure that the hose always has a slight slope ! 
 

 

 

 
 

6.  Cleaning 
 

6.1 Cleaning the housing 

 

 

Please disconnect the mains plug before cleaning the construction dryer. 

 

Only use mild cleaning agents to clean your construction dryer. 

 

NEVER spray your building dryer (e.g. with water or similar). 

 

6.2 Cleaning the air filter screen and the cooling fins 

 

The air filter screen at the front of the air intake filters lint, hair and coarse construction dust. Furthermore, the air 
filter ensures that less dust is deposited on the cooling fins, thus ensuring higher efficiency. Too much dust and dirt 
in the filter sieve or on the cooling fins reduces the dehumidification performance and can lead to a loss of 
efficiency in the 
In the worst case, this can even cause damage to your construction dryer, so the following applies in the case of 
coarse soiling or in rooms with a lot of construction dust: clean the air filter screen and also the evaporator unit 
regularly! 

 

 

Clean the filter whenever it can be assumed that the air intake is reduced by the dirty fan screen or that dirt and 
dust has been deposited on the cooling fins. (This can sometimes even be the case daily on dusty construction 
sites. ) 

 

Switch off the unit and disconnect the mains plug ! 

 

Open the front door where the air filter screen is attached as follows: Reach under the top two metal slats and 
open the front panel by gently jerking it away from the unit. 

 

The air filter screen is attached to the inside of the front fairing. Now remove the retaining rods of the air filter 
screen by passing the retaining rods through the upper and outer holes of the outer frame. 

 

Now you can remove the air filter screen. Wash the dirty sieve well under lukewarm water or vacuum it out 
thoroughly with a hoover. 

 

Condensation 

tank 

Sealing plug

 

Plastic tap 

Side hose hole 

Lower hose hole 

Summary of Contents for WDH-500AH

Page 1: ...ct To ensure that you get a lot of enjoyment from this product here are a few more tips In case of any problems We hope that the unit meets your expectations If despite the greatest possible care ther...

Page 2: ...e base plate of the building dryer using the 10 mm spanner C Insert one axle clamp on each side through the small holes at the level of the outside of the dryer housing and then bend them up or apart...

Page 3: ...supply to the unit otherwise it can lead to a reduction in performance and in the worst case to overheating and or fire Please always keep a distance of approx 20 cm to the wall to avoid possible ove...

Page 4: ...mes heat Please note that the refrigerant is odourless and therefore a leak cannot be detected immediately by an emerging odour If refrigerant leaks it may ignite or explode especially in poorly venti...

Page 5: ...OFF SWITCH Increase button the target moisture Lowering button the target moisture 1 Air intake front panel 2 Filter behind the front panel 3 Transport handle 4 Display and control panel 5 Electricit...

Page 6: ...lights up automatically The target humidity value is already preset to 60 r l by default The unit is programmed so that the compressor switches on for dehumidification as soon as the selected target h...

Page 7: ...ensuring higher efficiency Too much dust and dirt in the filter sieve or on the cooling fins reduces the dehumidification performance and can lead to a loss of efficiency in the In the worst case this...

Page 8: ...50 ltr day 30 C 80 r h Air circulation Approx 350 m3 h Compressor Rotary compressor Dimension H W D 925 x 605 x 462 mm Weight 31 kg Waterproofness IPx0 Cooling pressure max 2 5 MPa Vapour pressure ma...

Page 9: ...authorised customer service To To make your warranty claim please enclose the original sales receipt with date of sale Excluded from the guarantee are Normal wear Improper applications such as overloa...

Page 10: ...____________________________ _________________________________________________________ _________________________________________________________ _______________________________________________________...

Reviews: