Operating recommendations:  
 

For good cooling results and for the most effective and economical operation, we give you the following 
recommendations:

 

 

 

We recommend a room size of up to 40 m² (100 m³) for this air conditioner. 

 

The minimum size of the room in which the unit is to be operated is at least 13m3 ! 

 

Lock windows and doors. 

 

Avoid direct sunlight into the room through windows and doors. It is best to close the shutters or curtains 
during the day. 

 

Keep the air filters of the air conditioner clean. 

 

Once you have reached the desired room temperature, reduce the operating strength of the air conditioner. 

 
Set-up and connection: 

1. connecting the exhaust hose for the warm air

 

 

     

 

 

The mobile air conditioner generates warm air for cooling the room. This warm exhaust air must be discharged to 
the outside. You can either discharge the warm exhaust air outside through a suitable hole (with the recommended 
diameter of 142 mm) in the wall (similar to a kitchen extractor bonnet) or through a gap of an open window/door. 

 

Note: Depending on the given conditions, it may be advantageous to use the closure strip provided for this 
purpose. The closure strip is variably adjustable and can thus ensure that no air from outside gets inside. 

1.1. 

Connect the warm air exhaust hose to the rear exhaust duct of your air conditioner by screwing the warm 

air hose on clockwise. 

1.2. 

If necessary, attach the supplied adapter to the other end of the exhaust air hose. 

1.3. 

Lead the exhaust air hose directly through the window gap/door gap to the outside so that the warm 

exhaust air can be blown out unhindered. 

1.4 

If you have installed the sealing strip on the window gap/door gap/wall, guide the exhaust air hose from the 

inside through the recess provided and then screw the adapter onto the exhaust air hose from the outside. 

Now the adapter can be connected to the sealing strip. 

1.5. 

When the air conditioner is  

not in use, close the end / adapter of the exhaust air hose with the adapter 

cover. 

 
 
 

Wall / Window

 

Adapter 

(outside) 

Summary of Contents for EDH-FGA1263B

Page 1: ...roper transport can sometimes occur despite careful instructions on the carton Therefore we ask you to let it stand upright for at least 4 hours before using it for the first time so that the refrigerant in the unit can settle again In case of any problems We hope that the unit meets your expectations If despite the greatest possible care there should ever be cause for complaint please contact us ...

Page 2: ...e Fig 2 This air conditioner is only approved for indoor use Only qualified personnel or electricians are allowed to open the unit Make sure that no moisture gets into or onto the unit Fig 3 Only use the recommended voltage for operating the unit Make sure that the power cable is unfolded untied before connecting it to the socket Please do not use the power cable as a pull cable for the air condit...

Page 3: ...er cable compartment 5 exhaust air cold 11 air intake 2 6 air filter screen 1 2 12 condensation water drain Accessories 13 exhaust air hose for warm air 14 adapter for connecting the warm air hose to the wall or window 15 adapter cover 16 closure strip for window gap 1 17 closure strip for window gap 2 18 sealing strip for window gap with connection point for warm air hose 19 condensation water dr...

Page 4: ...ough a suitable hole with the recommended diameter of 142 mm in the wall similar to a kitchen extractor bonnet or through a gap of an open window door Note Depending on the given conditions it may be advantageous to use the closure strip provided for this purpose The closure strip is variably adjustable and can thus ensure that no air from outside gets inside 1 1 Connect the warm air exhaust hose ...

Page 5: ...mum of 150 cm However for maximum efficiency and economy we recommend the shortest possible length Warning The length of the exhaust air hose is specially adapted to the specification of the air conditioner Please do not replace the exhaust air hose with another or do not try to extend it This may cause damage or loss of performance to your unit 2 the air filter 2 1 Remove the two filter units 4 f...

Page 6: ... mode G Low air circulation signal light 8 TiO2 ION button inactive on this unit type H Signal light when timer is activated I Signal light when night mode is activated J Signal light for TiO2 ION operation inactive K Signal light condensation water tank is full Instructions for use 1 Commissioning 1 1 Insert the mains plug properly into the socket 1 2 Check that the exhaust hose for the hot air i...

Page 7: ...he automatic mode signal light B By selecting the automatic mode the air conditioner attempts to reach or permanently maintain the factory set temperature target of 24 C and then automatically switches off the compressor after this value is reached Note Using the automatic mode on units without a heating function makes only limited sense as the auto mode was originally designed to maintain a const...

Page 8: ...ion night mode cannot be activated in the following operating modes AUTOMATIC MODE or FAN MODE 8 Remote control All functions and settings as described in points 1 7 above can also be operated adjusted with the remote control supplied The remote control requires two AAA batteries not included 9 Error display The air conditioner detects malfunctions and displays them in the unit s display panel If ...

Page 9: ...ak cannot be detected immediately by an emerging odour Make sure that the outlet of the exhaust air is always given and not obstructed by other objects Only appropriately trained specialists are permitted to carry out repairs to the cooling lines and the compressor Always contact a specialist in case of a problem Ensure a minimum distance of at least 50cm from open flames and heating elements Cond...

Page 10: ...can drain off easily unhindered see fig below 3 The drain hose can be extended or also replaced In this case please use a suitable hose A inch hose is best suited fitting Maintenance Always disconnect the mains plug before cleaning your air conditioner To keep the effectiveness and service life of your air conditioner high please clean this unit regularly Cleaning the housing Use a soft and damp c...

Page 11: ...itions The unit does not cool enough Make sure that the unit is not in direct sunlight Make sure that no windows or doors are open Is it possible that there are too many heat sources in the room Please consider that every person every window exposed to sunlight and every electrical appliance produces heat and therefore the cooling capacity of the air conditioner may no longer be effective enough M...

Page 12: ...in accordance with EU standard EN 14511 as well as EU safety and test regulations EN 60335 2 40 COOLING dry temperature 35 C wet temperature 24 C Other Warranty statement Notwithstanding the statutory warranty claims the manufacturer grants a warranty in accordance with the laws of your country but at least 1 year in Germany 2 years for private individuals The warranty begins on the date of sale o...

Page 13: ...ty tested according to EN 55014 1 2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 Correct disposal of this product Within the EU this symbol indicates that this product should not be disposed of with household waste Waste equipment contains valuable recyclable materials that should be recycled and not harm the environment or human health through uncontrolled waste disposal Therefore pleas...

Page 14: ..._____________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ ______________________...

Reviews: