Figure 1

    WARNING:

 

The Bumper Monitor contains moving parts . Keep hands, fingers and objects away  

   

 

from pinch points .

    WARNING:

 

Not designed for explosive environments .

    WARNING:

 

Exceeding the maximum pressure and flow of the Bumper Monitor or nozzle may cause damage .

    WARNING:

 

Do not disconnect Bumper Monitor from quick disconnect base while flowing .

GENERAL INSTRUCTIONS

•  Review the instructions, wiring diagram, component layout and rotational stops diagram before installing this

  unit . This unit operates on 12 or 24 volt DC depending on the unit chosen . All electrical current flows through the
  wires . The Bumper Monitor does not act as a ground . 

Page 02

• Not recommended for use in salt water applications.
• For firefighting by trained firefighters only.
• For use with water or standard fire fighting foams only. After use with foam, flush with fresh water.
• Do not use the nozzle as a forcible entry tool.
• Drain the monitor and nozzle after use to prevent “freeze damage”.
• Ensure that the thread in the nozzle swivel matches the thread on the Bumper Monitor outlet. Do not 

 

   overtighten the nozzle .

• The Bumper Monitor, nozzle, logic box, control boxes and field adjustable rotation stops are made for optimal

   performance, Do not alter in any manner .

• Do not install shutoffs on the outlet of the Bumper Monitor.

Top View

Side View

45

°

10-

9/

16

17-21/

32

5 5/

8”

13-3/16

90

°

 14-7
/16

8-29/32

11-7/16

8-3/8

1-1/2 NH OUTLET

Summary of Contents for 3462

Page 1: ...122386 TABLE OF CONTENTS STYLE 3462 FORESTRY BUMPER MONITOR INSTALLATION OPERATING and MAINTENANCE INSTRUCTIONS English 1 8 Deutsch 9 16...

Page 2: ......

Page 3: ...lt motors 23 volts while operating Mass 23 lbs 10 4 kg with out nozzle or quick disconnect base Maximum Flow 300 GPM 1135 lpm Maximum Pressure 200 PSI 14 bar Noise Emission 94 Db 1m with Maximum Flow...

Page 4: ...The Bumper Monitor does not act as a ground Page 02 Not recommended for use in salt water applications For firefighting by trained firefighters only For use with water or standard fire fighting foams...

Page 5: ...sets the upper limit of the elevation The monitor is shipped with elevation stops at 90 above horizontal and 45 below horizontal to meet NFPA All other vertical positions are achieved by switching pl...

Page 6: ...Remove gearbox housing 19 from the motor assembly 15 6 Replace o ring seal 18 on the gearbox housing 19 7 Attach the new motor assembly 15 to the gearbox housing 19 making sure all four screws 21 are...

Page 7: ...USB ConnectorManual Override Crank Power Valve Connector CAN Connector Guide Pins Quick Disconnect Front of Monitor Latch Pin Hole Shown at Mid Travel 45 45 Elevation Stop 45 45 to 90 Elevation Stop...

Page 8: ...TOP ELEVATION STOPS 90 45 ELEVATION STOPS 90 20 ELEVATION STOPS 45 45 ELEVATION STOPS 45 20 STOP PLUG STOP STOP PLUG PLUG STOP PLUG PLUG STOP PLUG STOP PLUG STOP STOP STOP PLUG ROTATION AND ELEVATION...

Page 9: ...P N 721290 VALVE HARNESS 20 FEET 60 1 2 TO DISCHARGE VALVE TO VEHICLE POWER TO CONTROLLER P N 721564 REV XX 3462 FORESTRY CONTROLLER POWER AND VALVE VVV BBBBB P N 721565 REV XX 3462 FORESTRY CONTROLL...

Page 10: ...ow our instructions or recommendations or anything else beyond our control WE MAKE NO WARRANTIES EXPRESS OR IMPLIED OTHER THAN THOSE INCLUDED IN THIS WARRANTY STATEMENT AND WE DISCLAIM ANY IMPLIED WAR...

Page 11: ...aximaler Durchfluss 1135 l min 300 G min Maximaler Betriebsdruck 14 bar 200 psi Ger uschbildung 94 dB bei 1m bei maximaler Durchflussleistung WARNHINWEISE ZUM PRODUKT WARNHINWEIS Die maximale Durchflu...

Page 12: ...e t durch die Kabel Der Frontwasserwerfer dient nicht als Erdung Draufsicht Seitenansicht Nicht f r die Anwendung in Salzwasser geeignet Nur f r die Feuerbek mpfung durch geschulte Brandbek mpfer geda...

Page 13: ...Der Wasserwerfer wird mit H henanschl gen bei 90 ber und 45 unter dem horizontalen Schwenkbereich geliefert Alle anderen Aufrichtpositionen k nnen eingestellt werden indem die Stecker und Anschl ge w...

Page 14: ...n 5 Das Getriebegeh use 19 von der Antriebsbaueinheit 15 nehmen 6 Den O Ring 18 am Getriebegeh use 19 austauschen 7 Die neue Antriebsbaueinheit 15 am Getriebegeh use 19 anbringen und dabei darauf acht...

Page 15: ...ite Verriegelungsstift USB Anschluss Manuelle bersteuerungshandrad Strom Ventilkabels stecker CAN anschlie en Leitpins Schnellabschaltung Vorderseite Monitor ffnung des Verriegelungsstiftes Shown at M...

Page 16: ...VERTIKALE SCHWENKANSCHL GE 90 20 VERTIKALE SCHWENKANSCHL GE 45 45 VERTIKALE SCHWENKANSCHL GE 45 20 ANSCHLAG STECKER ANSCHLAG ANSCHLAG STECKER STECKER ANSCHLAG STECKER STECKER ANSCHLAG STECKER ANSCHLAG...

Page 17: ...P N 721290 VENTILKABEL 20 FU 60 1 2 ZUM AUSLASSVENTIL ZUM FAHRZEUGSTROM ZUM REGLER P N 721564 REV XX 3462 FORESTRY CONTROLLER POWER AND VALVE VVV BBBBB P N 721565 REV XX 3462 FORESTRY CONTROLLER CAN...

Page 18: ...trolle WIR BERNEHMEN KEINE GEW HRLEISTUNG WEDER AUSDR CKLICH NOCH STILLSCHWEIGEND DIE NICHT IN DIESER GEW HRLEISTUNGSERKL RUNG BER CKSICHTIGT IST UND WIR LEHNEN JEDE STILLSCHWEIGENDE GEW HRLEISTUNG F...

Reviews: