AKO-16524A / AKO-16525A
Warnings
-If the equipment is used without adhering to the manufacturer's instructions, the device safety
requirements could be compromised. Only probes supplied by AKO must be used for the unit to operate
correctly.
2
-From -40 ºC to +20 °C, if the NTC probe is extended to 1000 m with at least a 0.5 mm cable, the maximum
deviation will be 0.25 ºC (cable for probe extension ref.
AKO-15586
. Earth the cable mesh at one end only).
-Only NTC type probes supplied by AKO must be used for the appliance to operate correctly.
-It must be installed in a place protected from vibrations, water and corrosive gases, where the ambient
temperature does not exceed the value indicated in the technical data.
-For the reading to be correct, the probe must be used in a place without thermal influences apart from the
temperature you want to measure or control.
-IP65 protection degree is only valid with the protection cover closed.
-The IP65 protection degree is only valid if the cables enter the device through a tube for electric co
gland with IP65 or above. The size of the glands must be suitable for the diameter of the tube used.
-Do not spray the unit directly with high-pressure hoses, as this could damage it.
Maintenance
Clean the surface of the unit with a soft cloth, water and soap.
Do not use abrasive detergents, petrol, alcohol or solvents, as this might damage the unit.
Presentation
The
AKO-16524A / 16525A
advanced controller for cold
room stores has a
SELFDRIVE
operating mode that
automatically controls (without parametrisation) the fans
and adaptively minimises defrosts to optimise the
performance of the cold room store: maximising time in set
point and minimising costs linked to energy consumption
and wear of components.
In order to evaluate the performance of the refrigeration
facility in detail, the CAMM (
AKO-58500
) module and the
applications for the AKO CAMM Tool and AKO CAMM Fit
mobile devices (available in App Store and in Google Play)
are included with the
AKO-16524A
controller . These applications provide several indicators on the actual operation
of the cold room that allow diagnosing possible design, usage or maintenance problems in the installation.
1652H4A02 Ed.09