![AKO Electronica AKO-52044 Manual Download Page 16](http://html1.mh-extra.com/html/ako-electronica/ako-52044/ako-52044_manual_2886531016.webp)
4.- Equipment description
4.1.- LED indicators
Coverage LED
Green constant:
Connected, good signal.
Green flashing:
Connected, weak signal.
Red flashing:
In the process of connecting/No signal.
Power supply LED
Green constant:
With power supply. Battery connected.
Green flashing:
With power supply. Battery NOT connected.
Red constant:
Working on battery power (without power supply).
Switched off:
No power supply. Battery not connected or not charged.
LEDs de entradas / salidas 1 y 2
Green flashing: Input active
Red flashing:
Output active
Red and green alternating:
Input and output active.
LEDs for inputs 3 and 4
Green flashing:
Input active
External antenna
Coverage LED
SIM card cover
Power supply LED
LEDs for inputs/outputs
LEDs for inputs
Reset
Digital inputs
Relay outputs
Power supply
input
4.2.- Battery mode operation
In the event of a power failure, the alarm can operate for approximately 1 hour on battery power. During this time
all of the alarm functions remain operational, including inputs and outputs.
In the event of a power failure or restoration of power, the alarm sends an SMS to the administrator (the first
number on the telephone list) (see page 19).
16
5204H401 Ed.01