SPECIFICATION FOR PLT-42TT PLASMA DISPLAY VER1.0
2-7
a.
Drop Test
200mm max.
b.
Vibration Test
1.
Forward and backward
2.
Right and left
3.
Up and down
30 minutes 1000 c.p.m
30 minutes 1000 c.p.m
30 minutes 1000 c.p.m
8.4 Power Management:
Mode
H-sync
V-sync
Video
Power dissipation
Normal
Pulse
Pulse
Active
Normal power
Stand-by
No pulse
No pulse
No video
Power off
Pulse
No pulse
Power saving
No pulse
Pulse
Blanked
Less than 5 watts
This Plasma display is Energy star compliant when used with a computer equipped with
DPMS.
Note: The power indicator LED color is green in normal state, yellow in stand-by
and power saving state.
9.
VIDEO & AUDIO
9.1
Video Signal Output (impedance 75 ohm)
(input signal at 1.0 Vp-p
±
±±
±
0.2Vp-p)
1.0 Vp-p
±
±±
±
0.2Vp-p