SPECIFICATION FOR PLT-42TT PLASMA DISPLAY VER1.0
2-6
6.1
RF Sensitivity (Peak)
VHF
CH 2 ~ CH 13
30dB Max.
UHF
CH 14 ~ CH 69
30dB Max.
CATV
CH A-5 ~ CH W+29
30dB Max.
6.2
AFT Pull-In Range
VHF
CH 2 ~ CH 13
±
±±
±
0.6MHz Min.
UHF
CH 14 ~ CH 69
±
±±
±
0.6MHz Min.
CATV
CH A-5 ~ CH W+29
±
±±
±
0.6MHz Min.
6.3
Picture IF Rejection
VHF
CH 2 ~ CH 13
50dB Min.
UHF
CH 14 ~ CH 69
50dB Min.
CATV
CH A-5 ~ CH W+29
50dB Min.
6.4
Picture Image Rejection
VHF
CH 2 ~ CH 13
40dB Min.
UHF
CH 14 ~ CH 69
35dB Min.
CATV
CH A-5 ~ CH W+29
35dB Min.
6.5
AGC Characteristics
AGC Figure Of Merit
50dB Min.
RF signal range in which video at PDP drops 6 dB from output level obtained
with 100mV input.
6.6
RF AGC Cut In Level
55dB
±
±±
±
2dB
6.7
FM/AM Rejection (100mV at SIF input)
14dB min
6.8
Noise Limits Sensitivity
VHF 45dB max
UHF 49dB max
7. RELIABILITY REQUIREMENT:
The MTBF needs 20000hrs under operation 25
±±±±
5
℃
℃
℃
℃
(half luminosity, motion picture)
8. REGULATORY REQUIREMENTS:
8.1 Safety Requirement:
a. UL
Safety of information technology equipment including
electrical business equipment
b. CSA
Safety of information technology equipment including
electrical business equipment
c. TUV
8.2 Emission Requirement:
The unit shall meet the EMI limits in all screen modes. For EMI testing, the unit must be failed
with the screen pattern consisting of scrolling capital “H” characters also the brightness
contrast will be adjusted to max. Level.
a. FCC class A part 15
8.3 Transit test