28
Model No: AC-S10HKX2
Version 1.0
2) Remove burrs
Remove burrs from cut edges of pipes.
Turn the pipe end down to avoid the metal powder entering the pipe.
Caution
: If the burrs are not removed, they may cause a gas leakage.
3) Flaring the pipes
Insert the flare nuts, mounted on the connection ports of both indoor and outdoor units,
onto the copper pipes. Some refrigerant gas may leak, when the flare nuts are removed
from the indoor unit, as some gas is charged to prevent the inside of the pipe from rusting.
Fit the copper pipe end into the bar of flare tool about 0~0.5mm higher .
Flare the pipe ends.
4) Tape the flaring portion to protect it from the dust or damages.
Indoor unit installation
Hook the indoor unit onto the upper portion of installation plate.(Engage the two hooks of the
rear top of the indoor unit with the upper edge of the installation plate.)
Ensure the hooks are properly seated on the installation plate by moving it in left and right.