OPERATION DETAILS
1. SAFETY CONTROL
3 minutes delay for compressor
The compressor is ceased for
3
minutes to balance the pressure in the refrigeration cycle in order to
protect the compressor.
59 seconds delay for reversing valve
The 4-way reversing valve delay for
59
seconds to prevent the refrigerant abnormal noise when the
HEATING operation is OFF or switched to other operation modes.
Over-current control
The compressor will be switched
OFF
when it is over-current for
5
seconds, and when the current is
normal and the compressor has been off for
3
minutes , the compressor will be turned
ON
.
Freeze preventive control
When the indoor pipe temperature falls below
–1
℃
during COOLING or DRY operation for 3
minutes, the compressor and outdoor fan motor turn
OFF
with buzzer 3 beeps . When the indoor pipe
temperature recovers to
5
℃
and the compressor has been off for
3
minutes, the compressor and
outdoor fan motor will be turned
ON
.
Overheating protection system
When overloading occurs during the heating operation, this system controls the outdoor fan motor
and compressor according to the indoor pipe temperature to prevent the overloading of the
compressor and restrain the rise in high pressure. When the indoor pipe temperature exceeds
53
℃
,
the outdoor fan motor will be turned
OFF
, and when the indoor pipe temperature falls below
49
℃
,
the outdoor fan motor recovers to
ON
. When the indoor pipe temperature exceeds
63
℃
, the appliance
will be turned
OFF
with 4 beeps of buzzer and cannot recover automatically.