13
6 Specifications
Type:
dynamic pressure gradient microphone
Polar pattern:
cardioid
Frequency range:
150 to 15,000 Hz
Sensitivity at 1000 Hz:
2.2 mV/Pa (–53 dBV re 1 V/Pa)
Electrical impedance at 1000 Hz:
≤
530
Ω
Recommended load impedance:
≥
2000
Ω
Connector:
D 542: fixed cable (3 m/10 ft.) w/stripped-
and-tinned leads
D 542 E: 3-pin XLR
Case material:
die-cast metal
Finish:
matte gray enamel
Size:
length: 345 mm (13.6 in.);
max. dia.: 35 mm (1.4 in.)
Net/shipping weight:
D 542: 275 g (9.7 0z.) / 422 g (15 oz.)
D 542 E: 285 g (10.1 oz.) / 334 g (11.8 oz.)
This product conforms to EN 50 082-1.
Frequency Response
Polar Diagram