background image

CEQ1/1 und CEQ1/1BB 

1/1 Precautions 

1.  

Spill no liquids on the equipment and do not drop any objects through openings in 
the equipment. 

2.  

Do not place the equipment near any heat sources such as radiators, heating ducts, or ampli­
fiers and do not expose it to direct sunlight, excessive dust, moisture, rain, mechanical vibrations, 
or shock. 

2. Installation 

Installing the CEQ1/1 properly is simple, and 
only requires attention to a few issues.  The 
CEQ1/1 should be used in a grounded metal 
rack.  The Expansion Out port of the CEQ1/1 
should be connected to the Expansion In 
port of the next device.  Note that if multiple 
AM8s are being used with the CEQ1/1, the 
CEQ1/1 should be connected to the last AM8 
in the chain.  Figure 2 shows the correct inter­
connection for CEQ1/1s. 

EQ In

 and 

Ref Mic In

 connections should be 

made with good quality braid or foil shielded 
twisted pair.  The shield should be used for 
the ground (Pin 1) connection.  If an unbal­
anced signal is used, the unbalanced signal 
lead should be connected to the “+” input 
terminal, while the unbalanced ground lead 
should be connected to both the “-” and 
ground terminals of the input connector. The 
reference microphone input has +15V phan­
tom power supplied at all times. 

Output connections to the 

EQ Out

 connec­

tor can be made balanced or unbalanced. 
If an unbalanced connection is desired, sim­
ply connect the unbalanced signal lead to 
the “+” output terminal, and the unbalanced 
ground lead to the output ground terminal. 

Leave the “-” output terminal unconnected. 

The 

EQ Thru

 connector is electrically in par­

allel with the EQ input.  If the EQ input is con­
nected unbalanced, the 

EQ Thru

 will also be 

unbalanced. 

PWR 

IN 

(CH40) 

OUT 

IN 

EXPANSION 

E

20 VAC 

RS232 

AS8 

(Master) 

AS8 

(Slave) 

CEQ1 

Switch in 
MASTER Position 

Switch in 
SLAVE Position 

IN 

LecNet 

(RS232) 

PWR  IN 

(CH40) 

20 VAC 

(CH40) 

IN 

E

20 VAC 

RS232 

OUT 

OUT 

PWR 

IN 

EXPANSION 

EXPANSION 

Figure 2 - Connecting multiple AS8s with the CEQ1/1 

16 

Summary of Contents for CEQ1/1

Page 1: ...odukt entspricht EN500 81 1 EN 500 82 1 EU Conformity This product conforms to EN 500 81 1 EN 500 82 1 Conformit CE Ce produit r spond la norme EN 500 81 1 EN 500 82 1 Conformit CEE Questo prodotto ri...

Page 2: ...CEQ1 1 und CEQ1 1BB 5 Nur CEQ1 1 5 CEQ1 1 Men optionen Bedienung ber Frontplatte 6 4 Ger ter ckseite 7 5 Einstellungen f r den Betrieb 7 Einstellung ber die Frontplatte nur CEQ1 1 8 Einstellung ber d...

Page 3: ...EQ1 1BB besitzt keine Bedienungselemente auf der Frontplatte und kann somit nur mittels Computer bedient werden Sollten Fragen bez glich der korrekten Einstellungsprozedur auftauchen so d rfen wir an...

Page 4: ...gkeitseinwirkung Regen Vibrationen oder Schl gen aus 2 Installation Die korrekte Installation des CEQ1 1 und CEQ1 1BB ist einfach einige wenige Dinge sind dabei zu beachten Der CEQ1 1 und CEQ1 1BB sol...

Page 5: ...erdrillten Mikrofonleitungen mit Folien oder Geflechtschirm erfolgen Der Schirm wird am Masseanschlu Pin 1 angeschlossen Wir ein unsymmetrisches Mikrofon verwendet so ist die Signalader an der Klemme...

Page 6: ...Bypass Funktion des Hochpa filters des CEQ1 1 Pop Suppress Threshold Erlaubt die Einstellung der Wirkung der DPS Funktion dynamische Poppger usch Unterdr ckung Der Einstellungsbereich betr gt 40dB bis...

Page 7: ...krofone an EQ OUT Symmetrischer Leitungspegel Ausgang des CEQ1 1 und CEQ1 1BB LecNet RS 232 Serial Port Bietet Zugang zur Steuerung einiger der Funktionen des CEQ1 1 und CEQ1 1BB Diese Schnittstelle i...

Page 8: ...AutoEQ Vorgangs Am Ende des Vorgangs kehrt die Anzeige zum Men Auto Equalize zur ck Denken Sie daran mit der Taste Save die neue Einstellung der AutoEQ Funktion abzuspeichern um diese nach Abschalten...

Page 9: ...er die pr zise Einstellung ist viel schwieriger Zus tzlich zu den 27 Frequenzb ndern besitzt der CEQ1 1 oder CEQ1 1BB zus tzlich ein zuschaltbares Hochpa filter 6dB Oktave bei 200Hz Die dynamische Pop...

Page 10: ...Device Receive S R 3 5MM 9 Pin Female T Stereo Plug D Subminiature LecNet Device Transmit LecNet Device Receive N C 1 Tip RXD 2 Ring TXD 3 AMX Sleeve Gnd N C 4 or Gnd 5 LecNet Port Crestron N C 6 Port...

Page 11: ...uenzen Genauigkeit 3 Anhebung Absenkung 15dB Hochpa filter 200Hz 6dB Oktave Poppger usch Unterdr ckung Dynamisches Hochpa filter max Eckfrequenz 1KHz 6dB Oktave Schwelle einstellbar von 40dBu bis 0dBu...

Page 12: ...CEQ1 1 und CEQ1 1BB 12...

Page 13: ...d CEQ1 1BB CEQ1 1 and CEQ1 1BB CEQ1 1 and CEQ1 1BB CEQ1 1 and CEQ1 1BB CEQ1 1 and CEQ1 1BB Automatic Equalizer Automatic Equalizer Automatic Equalizer Automatic Equalizer Automatic Equalizer Manual Ma...

Page 14: ...ng Instructions 19 Resetting the EQ1 to Factory Defaults 19 6 TROUBLESHOOTING 19 7 Specifications 20 8 Serial Port Hardware and Software 21 9 Serial Port Commands Available 22 General Device Commands...

Page 15: ...tem is a dynamic high pass filter which reacts only to low frequency transients Breath pops or bass boost from speaking too close to a directional microphone are both significantly reduced Since the f...

Page 16: ...should be used for the ground Pin 1 connection If an unbal anced signal is used the unbalanced signal lead should be connected to the input terminal while the unbalanced ground lead should be connect...

Page 17: ...rned to factory default condition Factory defaults are as follows 1 Stored EQ curve is reset to flat 2 User Target curves 1 3 are reset to Factory curves 1 3 3 Pop Suppress system is set to off 4 LCD...

Page 18: ...s the display will revert to the Auto Equalize menu Remember that the SAVE button must be pressed after the AutoEQTM process to store the new EQ curve to permanent memory 4 Rear Panel Description CEQ1...

Page 19: ...uto Equalize menu option and press SELECT The Pink Noise Level sub menu prompts for an appropriate pink noise level to be set The EQ1 will indicate when the pink noise level is adequate Press the SELE...

Page 20: ...Constant Q 3 center frequency accuracy Cut Boost Range 15dB Low Cut Filter 200Hz 6dB octave Pop Suppression Filter DPS Dynamic high pass maximum filter corner frequency is 1kHz 6dB octave Threshold r...

Page 21: ...d TX Chassis Gnd RTS CTS 3 Ring Tip 2 Sleeve 7 Host 1 Serial 4 Port 5 PC 6 DSR DTR 20 LecNet Device Transmit LecNet Device Receive LecNet Device to AMX or Crestron S R 3 5MM 9 Pin Female T Stereo Plug...

Page 22: ...8 bit value and the second byte is 1 if the MSB of the data byte is 1 or 0 if the MSB of the data byte is 0 Each CEQ1 1 command must be preceded by the address of the device to be controlled If a dev...

Page 23: ...of the CEQ1 1 Local or Remote 0 indicates Local mode 1 indicates Remote Host sends command 21 Host receives 1 byte EQ1 Mode Set Local Remote Mode Allows the Local Remote status of the CEQ1 1 to be set...

Page 24: ...ge is from 0 127 0 96 corre sponds to 0 48dB attenuation in 5dB steps 97 126 corresponds to 49 78dB in 1dB steps and 127 is 100dB mute Host sends command 6 Host receives 1 byte Attenuation level see a...

Page 25: ...o 120 60 to 10 are valid If a 0 is returned the level is below 60 and if a 255 is returned the level exceeds 10 Host sends command 14 Host receives 1 byte 20 120 0 or 255 BP filter level Input Output...

Page 26: ...Lowcut out 1 Lowcut in Set Lowcut Filter Allows the state of the Lowcut filter to be set Byte 1 is the Lowcut Filter setting 0 Out 1 In Byte 2 is 0 or 1 and indicates whether or not to save the new va...

Page 27: ...27 CEQ1 1 und CEQ1 1BB Notes...

Page 28: ...onics Inc 581 Laser Rd NE Rio Rancho NM 87124 USA 505 892 4501 800 821 1121 Fax 505 892 6243 http www lectrosonics com AKG Akustische u Kino Ger te Gesellschaft m b H SCJ AKG Ltd 2F Yoyogi Living 5 21...

Reviews: