12
COMPLETE INSTALLATION(FOR NON-
VENTED(RECIRCULATING) INSTALLATION ONLY
Step 1: Do not install exhaust pipe, remove the grease filters, locate the blower inside the hood
Step 2: Attach the carbon filters to both sides of the blower
Step 3: Twist the carbon filter until it is in the locking position
Step 4: Reinstall the grease filters, reconnect the power.
INSTALL VENT COVERS
When using both upper and lower vent covers, push lower cover down onto hood and lift upper cover to
ceiling and install with two M5 x 12 screws
.
NOTE:
For vented installations, the upper vent cover maybe reversed to hide slots.
A. Upper chimney
B. Lower chimney
C. M5 X 12 screw
D. Chimney mounting bracket