panel buses to increase reliability. Hub buses are independent. Therefore, if one
of the buses fails for some reason, the devices on other buses will continue to
work.
We recommend connecting wired devices via the
Ring connection method
. This
way, if the line is broken, the devices will be connected to Hub Hybrid via the
Star connection method
and will continue to transmit events and alarms to the
hub. Notification about the line open fault will be sent to users and the security
company.
When connecting via the
Ring connection method
, connect two buses per one
segment and reduce the maximum length of the wired connection to 500 meters
(when connected via the
Star connection method
— to 2,000 meters).
Hub Hybrid supports
Star connection method
only.
Ring connection method
will be
implemented in the future OS Malevich updates.
When connecting devices, do not twist the wires together; solder them. The
ends of the wires that will be inserted into the siren terminals should be tinned
to increase the reliability of the connection.
Follow the polarity and connection order of the wires. Securely fasten the wires
to the terminals. If the device body provides fasteners for cables, secure the
cable with ties.
To connect a detector or device:
1.
De-energize and turn off the hub. Disconnect the backup battery.