background image

the polarity of the connected wires. If there is no power even after reconnecting,
please contact the Support Service.

We recommend using zinc-air alkaline batteries for long-term autonomous operation.
Before connecting such a battery, make sure that all the stickers have been removed,
and valves capping the air access are open. If possible, leave the battery with access to
air for up to 2 hours. This will start a chemical reaction inside and ensure proper
functioning.

Maintenance

The device does not require technical maintenance.

Tech specs

Compatibility

Hub 2 and Hub 2 Plus

Input voltage

4.2-16 V DC

Output voltage

4.8 V DC ± 5%

Switch on voltage

4.2 V DC ± 2.5%

Switch off voltage

3-3.4 V (depending on load)

Max input current

2,2 А on 4,2 V; 0,5 А on 16 V

Max output current

1,5 A

Temperature range

from -10°C to +40°С

Humidity

Up to 75%

Connection to mains

Socket: 6.5 × 2 mm 
Plug: 5.5 × 2,1 mm

Dimensions

98 × 70 × 17 mm

Weight

26 g

Service life

10 years

Compliance with standards

Summary of Contents for 6V PSU Hub 2

Page 1: ...installed by a qualified electrician only Before installing the power supply make sure that the device is disconnected from the mains When installing the 6V PSU Hub 2 Hub 2 Plus follow the general el...

Page 2: ...artBracket mounting panel shifting it down with force 2 Switch off the device holding the power button for 2 seconds 3 Disconnect power and Ethernet cables Wait 5 minutes for the capacitors to dischar...

Page 3: ...5 Remove the screws attaching the boards to the device body 6 Carefully remove both boards keeping them in the same plane and not disconnecting them There is a connector between boards do not break it...

Page 4: ...nboard using the eight pin connector between them Do not warp or bend the antennas while replacing the board this can cause the device to malfunction Please note the board contacts should be plugged i...

Page 5: ...over The SIM card slots power and Ethernet sockets should match accurately and fit the corresponding sockets and the power button should not be stuck Change the information about input voltage on the...

Page 6: ...up to 2 hours This will start a chemical reaction inside and ensure proper functioning Maintenance The device does not require technical maintenance Tech specs Compatibility Hub 2 and Hub 2 Plus Input...

Page 7: ...r 2 years after the purchase If the device does not function correctly please contact the Support Service first In half of the cases technical issues can be solved remotely Technical support 1 6V PSU...

Page 8: ...Subscribe to the newsletter about safe life No spam Subscribe Email...

Reviews: