background image

5

Subject to change without notice  |  83030000aUK – Translation of the original operating manual |  ait-deutschland GmbH

Contact

Addresses  for  purchasing  accessories,  for  servicing 

or  for  answers  to  questions  about  the  unit  and  this 

operating manual can be found on the internet and are 

kept up-to-date.

  www.ait-deutschland.eu

Warranty / Guarantee

For warranty and guarantee conditions, please refer to 

the purchase documents.

 NOTE

Please contact your dealer about all matters 

concerning warranties and guarantees.

8  Disposal

When decommissioning the unit, always comply with 

applicable laws, directives and standards concerning 

recovery, recycling and disposal.

Scope of delivery

 

● Storage tank

 

● 1 sensor for the regulator

1.  Inspect the delivery for outwardly visible signs of 

damage.

2.  Check to make sure that the delivery is complete. 

 

Any  defects  or  incorrect  deliveries  must  be 

claimed immediately.

9.1  Accessories

 IMPORTANT

Use only original accessories from the manu-

facturer of the unit.

10 

Transport, Installation, 

Assembly

Observe the following when performing all work:

 IMPORTANT

The  tank  must  be  installed  in  a  frostproof 

room, to prevent frost damage to the storage 

tank, pipe system and connections.

 NOTE

Install the storage tank as close as possible 

to the heat generator, to keep the heat losses 

as low as possible. Ensure the shortest pos-

sible pipe lengths to the load.

 IMPORTANT

The floor or ground at the place of installation 

must be dry, firm and able to safely support 

the weight of the tank.

In  the  case  of  wall-mounted  storage  tanks, 

the wall must have sufficient load-bearing ca-

pacity to safely carry the weight of the stor-

age tank when full.

  “Technical  Data",  page 7,  for  the  respective 

model

10.1  Transport to installation location

To  avoid  damage  during  transport,  transport  the 

storage tank  (secured on the wooden pallet) to its final 

installation location using a lifting truck.

 CAUTION

Make sure to secure tank against slipping 

during transport.

 CAUTION

The tank can tip over when being removed 

from the wooden pallet and during 

transport with a hand truck or lifting 

truck.  This can result in personal injuries 

and damage.

 

► Take  suitable  precautions,  which  prevent 

the tipping hazard.

 

► Dispose of the transport and packaging materials 

properly and under ecological aspects.

Summary of Contents for WPSK 40Split

Page 1: ...UK 83030000aUK Translation of the original operating manual Accessories for heat pumps Operating Manual Buffer Tanks Split...

Page 2: ...he respective model This operating manual is intended only for persons assigned to work on or operate the unit Treat all constituent parts confidentially The information contained herein is protected...

Page 3: ...posal 5 9 Scope of delivery 5 9 1 Accessories 5 10 Transport Installation Assembly 5 10 1 Transport to installation location 5 10 2 Installation 6 10 3 Installation of the sensor for the regulator 6 1...

Page 4: ...rsons who are able to understand the activities and the resulting consequences and can car ry out the necessary activities Children and adults who are not experienced in hand ling the product and do n...

Page 5: ...ng when performing all work IMPORTANT The tank must be installed in a frostproof room to prevent frost damage to the storage tank pipe system and connections NOTE Install the storage tank as close as...

Page 6: ...On site install the sensors included with the tank for the regulator in the sensor pockets provided Position Dimensional drawings from page 8 for the respective model 2 Connect the sensor to the regul...

Page 7: ...GW bar 6 6 Test pressure bar 9 9 Max operating temperature C 5 I 95 5 I 95 General unit data Dimensions Diameter Height see dimensioned drawing for rest mm mm 445 495 524 855 Tilt dimension mm 1005 He...

Page 8: ...2 Legende DE819513 Technischen nderungen vorbehalten Alle Ma e in mm A Vorderansicht C Draufsicht A C 495 330 445 4 3 2 1 Keys UK81513 All dimensions in mm Pos Name Dimension A Front view C Plan view...

Page 9: ...behalten Alle Ma e in mm A Vorderansicht C Draufsicht G Detailansicht A 4 3 2 1 A B C D E F Schutzvermerk ISO 16016 beachten Keys UK819424a All dimensions in mm Pos Name Dimension A Front view C Plan...

Page 10: ...nsicht iraum f r Servicezwecke A 6 5 4 3 2 www ait deutschl D 95359 Kase Industriestra ait deutschland G 4 3 2 Zust nderungstext Datum Von Datum N Erstellt Gepr Norm 09 06 20 Marki toleranz Allgemein...

Page 11: ...1001 MFS600S 15028001 WWS 405 2 15211101 MFS 830S 15028101 WWS 507 2 15211201 MFS 1000S 15039901 SWWS 404 2 15211301 WTPSK 100 Split 15079201 SWWS 506 2 15211401 WPSK 40 Split 15079101 814 2013 EN 128...

Page 12: ...ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf www ait deutschland eu UK...

Reviews: