background image

  

 

I.  

Cleaning and/or changing the filters: 

 

1. 

Pull down on the grille tabs until they snap out of place to remove the grilles from the ceiling assembly 
(See Figure 2). 

 
2. 

Lower the grille and filters from the ceiling assembly. 

 
3. 

Take filters out and either clean or exchange them with other filters (See Figure 2). 

 

Note: 

If replacement filters are necessary, the filters can be purchased from your local dealer or distributor. 

 

II.  

Service Person 

 

A. 

Electrical – All electrical work and/or inspection should be performed only by qualified service 
personnel.  Contact your nearest Coast to Coast authorized Service Center if electrical problems should 
arise. 

 
B. 

Check Points – Failure to start or to cool the air are sometimes problems with air conditioning units.  
The Coleman-Mach RV air conditioner is designed to operate on 230-240 volt, 50 Hz electrical power.  
If the compressor on the air conditioner fails to start, check with your Coast to Coast authorized Service 
Center to determine that the proper wire size is connected to the unit, the proper circuit breakers are 
installed as protection devices on the electrical circuit and the proper sized extension cord is being used 
for the distance covered from the utility outlet to the RV. 

 
 

If the air conditioner continues to trip the circuit breakers, have an electrician check the starting 
amperage and running amperage on the unit.  If the circuit breakers continue to trip and the electrical 
consumption is found to be normal, it will require the replacement of the faulty circuit breaker. 

 
 

If all electrical power to the air conditioner is normal but neither the fan nor the compressor will operate, 
the connector plug located behind the ceiling assembly control box should be checked to determine 
whether it is faulty. 

 
 

On the heating-cooling air conditioner models, if all electrical power to the unit is normal and the fan 
runs but you never get any heated air, even after momentarily removing power and waiting ten minutes 
per Item IV (Heat Operation) above, then the electrical plug to the heating unit should be checked for a 
secure connection.  If this does not correct the malfunction, the heating thermostat or limit switch may 
be faulty. 

 
C. 

Mechanical Integrity – The air conditioner should be inspected periodically to be sure that the bolts 
which secure the unit to the roof are tight and in good shape.  Also, an examination of the plastic shroud 
covering the air conditioner on top of the roof should be made periodically.  Be sure the four mounting 
screws and washers are snug and holding the shroud to the air conditioner.  Also examine the shroud to 
be sure it is not developing cracks or has suffered damage from impact. 

 

 
 
 
 
 

-6- 

“More information https://www.caravansplus.com.au"

Summary of Contents for Coleman-Mach 4735 Series

Page 1: ...IR CONDITIONER Service Contact Coast to Coast RV Services Pty Ltd PO BOX 415 REGENTS PARK DC NSW 2143 Australia Tel 61 2 9645 7600 technical coastrv com au Coleman is a registered trademark of The Coleman Company Inc used under license Mach is a registered trademark More information https www caravansplus com au ...

Page 2: ...umber of the unit Both numbers can be found on the data label on the unit Model No ________________________ Serial No ________________________ II OPERATING GUIDELINES The air conditioner is designed to provide cooling and dehumidification An electric coil provides heating in cool weather Note The electric heating assembly is intended to take the chill out of the indoor air when the air is a few de...

Page 3: ...ons 9400 ceiling assemblies will have the knobs at the bottom of the ceiling assembly See Figure 2 The Operation section explains the operational characteristics of each mode of operation B The Thermostat temperature control In the cooling mode the thermostat regulates the ON and OFF temperature setting at which the compressor will operate The thermostat also controls the ON and OFF temperature se...

Page 4: ...efrost before normal cooling operation is resumed During this time operate the unit in the HIGH FAN position with the system at maximum air flow When increased or full air flow is observed the cooling coil should be clear of ice III Short Cycling When an air conditioner is in operation its compressor circulates refrigerant under high pressure Once off it will take two to three minutes for this hig...

Page 5: ...of the biggest advantages to your new Coleman Mach air conditioner is that the maintenance needed to keep the unit in good care is minimal In fact about the only thing you the owner must take care of is the cleaning and replacement of the filters Filters are made from long life non allergenic natural fibers or foam which can be cleaned and reused and which completely filter the circulated air when...

Page 6: ...s to trip the circuit breakers have an electrician check the starting amperage and running amperage on the unit If the circuit breakers continue to trip and the electrical consumption is found to be normal it will require the replacement of the faulty circuit breaker If all electrical power to the air conditioner is normal but neither the fan nor the compressor will operate the connector plug loca...

Page 7: ...ess the filters pull on the tabs on the return air grilles The filters should be washed in warm water or vacuumed clean and replaced The filters should be inspected every 2 weeks and cleaned as required Note If the unit is operated in a dusty environment the filters should be inspected and cleaned more frequently FIGURE 2 7 Tabs to access filter Tabs to access filter More information https www car...

Page 8: ...me type rather than being repaired Refurbished parts may be used to repair the goods 3 WHAT THE CLIENT MUST DO TO CLAIM THE WARRANTY 3 1 To claim the benefit of the warranty the Client will need to sequentially i first contact the Supplier and ii present the defective Goods to the Supplier for inspection including inspection for defective workmanship or otherwise provide evidence of the claimed De...

Page 9: ...hould be referred to the installer The Goods must be installed in accordance with the Manufacturer s instructions and any relevant legislation or code 6 3 This warranty covers the Client only and it is not transferrable if the Goods are sold by the Client during the warranty period 7 WARRANTY EXCLUSIONS 7 1 This warranty will not apply where i the Goods have been improperly modified or repaired or...

Page 10: ...ox Yes No Receipt No Description of defects Give as much detail as possible Use a separate page if required Date of purchase services provided I hereby declare that the information provided above is true and correct and to the best of my knowledge and belief and I have complied with all the conditions of the warranty Signed Name please print Dated Please note the issue or completion of this form b...

Page 11: ...RV Products Division Airxcel Inc RV Products Division P O Box 4020 Wichita KS 67204 1976 671 Rev 1 3 15 PP More information https www caravansplus com au ...

Reviews: