Introduction to Wiring
Introduction to Wiring
©Aqua-Hot®
125DN Installation Manual
REV 220419
©Aqua-Hot®
125DN Installation Manual
REV 220419
p. 25
p. 24
Wiring the Aqua-Hot
This section will introduce the basic considerations,
practices, and information necessary to wire the Aqua-Hot to
any relevant RV-side systems.
\
The following section will outline the basic pin out information
for the two RV-side plugs (J6 and J8.)
J7 Plug:
The J7 plug is responsible for managing all zone fan power
connections, and boost pump supply and return.
Manufacturer
Part No.
Common Name
TE Connectivity 1-480706-0
9-Position Mate-N-Lock
TE Connectivity
350550-1 Mate-N-Lock Power Contacts
Once all the required hardware has been acquired, wire the J7
plug according to the table below. J7-9 is not used.
Pin Number
Function
Connect To
J7-1
Fan 1 Supply
Zone 1 Fans (+)
J7-2
Fan 2 Supply
Zone 2 Fans (+)
J7-3
Fan 3 Supply
Zone 3 Fans (+)
J7-4
Fan 1 Ground
Zone 1 Fans (-)
J7-5
Fan 2 Ground
Zone 2 Fans (-)
J7-6
Fan 3 Ground
Zone 3 Fans (-)
J7-7
Boost Pump Supply
Boost Pump +
J7-8
Boost Pump Ground
Boost Pump -
J7-9
UNUSED
UNUSED
1
2
3
4
5
6
7
8
9
J7 Wire insertion view shown
J8 Plug:
The J8 plug is meant to handle the zone thermostats and House
Power Sense functionality. House power sense functionality will
be described in detail later in this manual.
Manufacturer
Part No.
Common Name
TE Connectivity 1-480710-0
15 Position Mate-N-Lock
TE Connectivity
350550-1 Mate-N-Lock Power Contacts
Once the required hardware has been acquired, wire the J8
plug according to the table below. Pins J8-10 through J8-15 are
not utilized.
Pin Number
Function
Connect To
J8-1
Zone 1 Thermostat In
Zone 1 Thermostat
J8-2
Zone 1 Thermostat
Supply
Zone 1 Thermostat
J8-3
UNUSED
UNUSED
J8-4
Zone 2 Thermostat In
Zone 2 Thermostat
J8-5
Zone 2 Thermostat
Supply
Zone 2 Thermostat
J8-6
UNUSED
UNUSED
J8-7
Zone 3 Thermostat In
Zone 3 Thermostat
J8-8
Zone 3 Thermostat
Supply
Zone 3 Thermostat
J8-9
House Power Sense
12V DC Power (+)
J8-10
UNUSED
UNUSED
J8-11
UNUSED
UNUSED
J8-12
UNUSED
UNUSED
J8-13
UNUSED
UNUSED
J8-14
UNUSED
UNUSED
J8-15
UNUSED
UNUSED
Installation must be performed by a professional installer
or technician as per national/local regulations.
Improper installation can cause property damage, injury, or
death.
Figure 52
Figure 53
1
2
3
4
5
6
7
8
9
10 11 12
13 14 15
J8 Wire Insertion View Shown
Wiring the Aqua-Hot
J3 Plug:
The J3 plug connects to the on-board RVC system of the RV. It is
a 4-pin connector with self contained power pins. See the
diagram below for the crimping information for the J3 plug.
Crimp these parts together using pliers.
Manufacturer
Part No.
Description
3M
37401-2165-000 FL 100
4-Position MALE Plug
3M
37104-2165-000 FL 100
4-Position FEMALE Receptacle
General
Cable
E2104S.41.02
4COND 22AWG WHT SHLD Cable
The parts listed above can be purchased from any major
electronics retailer. Only the parts listed above are approved for
use in the Aqua-Hot.
Pin Number
Description
J3-1
12V DC Power
J3-2
Data
J3-3
Data
J3-4
Ground
12V DC Power (J3-1)
Ground (J3-4)
Data (J3-2, J3-3)
Figure 54
Wiring the Aqua-Hot