3.2 Outdoor frequency control
3.2.1 Compressor running frequency range: 30-91RPS.
3.3 Electronic expansion valve (EEV) control:
3.3.1 Electronic characteristic:
Max. open angle 500 Pulse
Driving speed
PPS
3.3.2 Initialization of EEV
EEV driving speed: open direction: 32MS; close direction: 32MS
3.3.3 Open angle limit of EEV
Unit
stop
Adjustable
upper limit
Cool/dry 250
(
E
)
480
(
E
)
heat
250
(
E
)
480
(
E
)
3.3.4 6
、
Standard open angle control
In Cool/Dry mode, standard open angle: outdoor ambient temp.
≥
22
℃
, 260pulse (E)
Outdoor ambient temp.
≤
22
℃
, 210pulse (E)
In heat mode, standard open angle: outdoor ambient temp.
≥
6
℃
, 240pulses (E)
Outdoor ambient temp.
≤
6
℃
, 160pulse (E)
3.3.5 When discharging temp. Td is too high or too low, modify the EEV angle
mode
Modification
process
Max.
modification
Cooling
If TD>106 degree and -1 degree /2 minutes, open
angle keeps between 106-50 .
-3
Cooling
If TD<50 degree and +1 degree /2 minutes, open
angle keeps between 50-106.
+3
Heating
If TD>100 degree and -1 degree /2 minutes, open
angle keeps between 100-50 .
-3
Heating
If TD<50 degree and +1 degree /2 minutes, open
angle keeps between 50-100
+3
3.4 4-way valve control in heating
50s later after compressor start up, the 4-way valve start to operate. When compressor stops
or unit is not in heating mode, the 4-way valve is closed after compressor stop for 2 minutes
and 55s.
compressor ON
OFF
4-way valve ON
OFF
50
秒(
E
)
2 minutes and 55s
3.5 Control of defrosting in heating
In heating mode, defrosting temp. sensor Te will check the frosting condition of outdoor heat
>_]]VbTZR\ <Zb >_^UZdZ_^Vb
35
Summary of Contents for YUDA060
Page 1: ...SERVICE MANUAL YUDA060 CAD060 Outdoor unit YUDA060 Indoor unit CAD060...
Page 7: ..._ VbTZR Zb _ UZdZ_ Vb 3 Dimension 580 25 1250 948 380 340 YUDA060 7...
Page 16: ...Name of Parts _ VbTZR Zb _ UZdZ_ Vb Air inlet Air outlet Compressor Inside of unit YUDA060 16...
Page 18: ...3 Installation dimension Unit mm _ VbTZR Zb _ UZdZ_ Vb 580 25 1250 948 380 340 YUDA060 18...
Page 40: ..._ VbTZR Zb _ UZdZ_ Vb 5 2 Indoor unit 5 2 1 PCB for indoor unit 40...
Page 59: ..._ VbTZR Zb _ UZdZ_ Vb 59...
Page 63: ..._ VbTZR Zb _ UZdZ_ Vb 63...
Page 64: ..._ VbTZR Zb _ UZdZ_ Vb wIWXb ST WPb c cWXb Ud RcX x 64...