6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit
XV26RCA
Outdoor Unit
GCXV26RCA
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor + Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.51
Power input
W
55
10.19
2,300
Rating conditions:
Indoor air temperature:
27
°
C
D.B. / 19
°
C
W.B.
Outdoor air temperature:
35
°
C
D.B.
Cooling
10.7
2,355
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor + Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.54
Power input
W
58
10.76
2,432
Rating conditions:
Indoor air temperature
20
°
C D.B.
Outdoor air temperature
7
°
C D.B. / 6
°
C W.B.
Heating
11.3
2,490
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor + Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.6
Power input
W
64
12.4
2,781
Rating conditions:
Indoor air temperature:
27
°
C D.B. / 19
°
C W.B.
Outdoor air temperature:
35
°
C D.B.
Cooling
13
2,845
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor + Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.64
Power input
W
68
12.06
2,727
Rating conditions:
Indoor air temperature
20
°
C D.B.
Outdoor air temperature
7
°
C D.B. / 6
°
C W.B.
Heating
12.7
2,795
Indoor Unit
XV30RCA
Outdoor Unit
GCXV30RCA
20