CONTROL SYSTEM
SM PNXADCI 1-A.1 GB
12-13
Selection
command
Go down one level
in the menu or
select an option.
Select
button
FAN mode
Escaping
command
Go up one level in
the menu
Escape
button
Oper/STBY
Note: the buttons above are selected according to RC8 design (refer to RC8 specifications) for the
technician convenient use.
1. The navigation type selection, remote controller or keypad, is set through software
parameter:
HMIType
=0 (keypad),
HMIType
=1 (remote controller)
2. The following table summarizes the remote controller commands:
Values on the IR protocol
Command
Type
Pressed
Button
SPT
Oper
FAN
Sleep
Horizontal
Louver
I-FEEL
Other bits
Up
‘+’
30
0
0
0
0
0
0
Down
‘-‘
16
0
0
0
0
0
0
Escape
Oper
Don’t care
1
0
0
0
0
0
Enter
FAN
Don’t care
0
01
0
0
0
0
Reserved
Sleep
Don’t care
0
0
1
0
0
0
Reserved
Horizontal
Louver
Don’t care
0
0
0
1
0
0
Reserved
I-FEEL
Don’t care
0
0
0
0
1
0
-
Other
20
0
0
0
0
0
0
Notes:
1. The zeros stated above must be checked in order to judge for proper message.
2. Proper checksum has to be performed according to the RC7 specifications.
3. For any remote controller command, the most right ‘dot’ will blink for 1 second in order to
acknowledge the command is received.
12.11.1.3
Active selection or status will be indicated by blinking the display.
12.11.2
Keys functionality
o
Scrolling will be done whenever the button is pressed.
o
When scrolling alpha values, if the scroll button is held in, the selection will change at the rate
of one step per second.
o
The display will not roll over during selection (for example stop/Ode/Dia/Stp/Par/stop)
12.11.3
Menus
12.11.3.1
General
All the green colored items will be deactivated for single split units.
12.11.3.2
Main Menu
Technician Test (tt)
Installation Test (it)