5.7.3
Heating Capacity (kW) - Run Mode
230[V] : Indoor Fan at High Speed.
ID COIL ENTERING AIR DB TEMPERATURE [
0
C]
OD COIL ENTERING
AIR DB/WB
TEMPERATURE [
0
C]
DATA
15
20
25
-15/-16
TC
3.46 2.96 2.46
PI
1.64 1.76 1.88
-10/-12
TC
4.57 4.07 3.57
PI
1.86 1.97 2.09
-7/-8
TC
5.40
4.90 4.40
PI
2.02 2.14 2.25
-1/-2
TC
5.81 5.31 4.81
PI
2.10 2.22 2.33
2/1
TC
6.09 5.59 5.09
PI
2.15 2.27 2.39
7/6
TC
8.10
7.60
7.10
PI
2.23
2.35
2.47
10/9
TC
8.52 8.02 7.52
PI
2.28 2.39 2.51
15/12
TC
8.94 8.44 7.94
PI
2.32 2.44 2.55
15-24
l
a
n
i
m
o
n
f
o
%
5
0
1
-
5
8
C
T
(Protection Range)
PI
80 - 120 % of nominal
LEGEND
TC
–
Total Heating Capacity, kW
PI
–
Power Input, kW
WB
–
Wet Bulb Temp., (
o
C)
DB
–
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OD
–
Outdoor
5.7.4
Capacity Correction Factors
Heating Capacity Ratio Vs. Outdoor Temperature
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
-15
-10
-5
0
5
10
15
Outdoor WB Temperature [ºC]
Ca
p
a
c
it
y
Ra
ti
o