3. OPERATION INSTRUCTION

A.MODE/RESET BUTTON

If■filter■LED■is■ON,■a■short■pressing■of■the■mode■

button will reset filter timer and turn off the filter 

clean LED.

If■filter■LED■is■OFF,■mode■button■is■used■for■forced■

operation mode in Cooling-Heating-OFF as circle.

If■filter■LED■is■OFF,■long■pressing■the■button,■will■

allow to enter

 diagnostic mode. 

For details

 please 

contact the technician. 

B.OPERATION INDICATOR 

Lights up in green during operation.

Blinks once when receiving message from remote 

controller.

Blinks for 3 seconds when cool mode is selected 

through mode button.

Blinks when the unit is in protection or fault state.

C.POWER INDICATOR

Lights up in 

red

 whenever power is on.

Blinks for 3 seconds when heat mode is selected 

through mode button.

D.TIMER INDICATOR

Lights up in yellow when 

TIMER 

mode 

at

 remote 

controllers is used.

Blinks after power off when Timers is set to show 

that timer counting is lost.

E.FILTER INDICATOR

Lights■up■when■air■filter■requires■cleaning.

F.SIGNAL RECEIVER

Receive

If the air-conditioner can not be operated by the Remote Control , it can be turned on 

for cooling or heating, or completely turned off , by every short pressing on MODE 

button (

A

) on the air-conditioner . The MODE button will change the operating status 

of  the  unit  between  -  COOLING  -  HEATMG  - 

OFF

  positions.

Enter into diagnostic 

mode by pressing MODE button at display for long time.

3.1  Special Tips

Summary of Contents for MVI Series

Page 1: ...IONS 1 PRECAUTIONS 2 OPERATION INSTRUCTIONS 4 TROUBLESHOOTING 6 ENGLISH Model DSV015 DSV018 DSV021 DSV024 DSV030 DSV036 Before using your air conditioner please read this operation instruction careful...

Page 2: ......

Page 3: ...sleeping In HEATING mode the reverse occurs the air conditioner lowers its temperature one degree every hour When SLEEP mode is activated the air conditioner will automatically turned off after seven...

Page 4: ...eating handle with care Do not apply any heavy pressure to of fan coil fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic e...

Page 5: ...start and stop air conditioner operation by disconnecting the power supply cord and so on Take care not to damage the power supply cord In the event of a malfunction burning smell etc immediately sto...

Page 6: ...in protection or fault state C POWER INDICATOR Lights up in red whenever power is on Blinks for 3 seconds when heat mode is selected through mode button D TIMER INDICATOR Lights up in yellow when TIME...

Page 7: ...r Failure Memory Function This function ensures that the unit will continuing working in last mode selected Otherwise the unit will keep OFF In this case please call your installer to set this functio...

Page 8: ...ict with the system operation mode System control mode isn t first win maybe force cooling heating or master indoor unit or control by OAT Stop using the unit or change the unit s operation mode to th...

Page 9: ...rning please change the mode to COOLING OR DRY OR FAN If setting mode is COOLING or DRY or FAN and A1 is warning please change the mode to HEATING If meeting following situation please call for your d...

Page 10: ......

Page 11: ......

Page 12: ...Part NO XXXXXXXX OM DLV DSV 1_A 1GB www airwell com...

Reviews: