1. Should the electrical outlet be located on the opposite side of the control panel, proceed 
as follows for relocating the electrical cable:
     a. Remove carefully the control knobs.
     b. Remove the side screws from the plastic front.
     c. Remove plastic front.
     d. Invert the cable position, so it can pass along the lower part of the unit front.
     e. Cut carefully with pliers the opposite opening on the plastic front.
     f.  Re-install the plastic front, the screws and the control knobs.

2. Demonstrate operation of the air conditioner to the customer and explain all its functions.

3. Explain filter removal, cleaning and re-installtion.

FINAL TASKS.

I n s t a l l a t i o n      a n d      M a i n t e n a n c e      I n s t r u c t i o n s

ROOM   AIR   CONDITIONER

SERIES

MAY

The conditioner is to be installed according to all professional rules, 
as well as the standards in force.  Before any handling, disconnect the unit.

MELBOURNE:  (03) 9271 3505
ADELAIDE:      (08) 8372 7866

SYDNEY:         (02) 9793 3644
NEWCASTLE:  (02) 4940 4652

BRISBANE:       (07) 3392 8113
PERTH:            (08) 9284 0800

PRINTED IN AUSTRALIA

ECP / MAY-inst

MANUAL MENU

Summary of Contents for May series

Page 1: ...to the cord may result in serious electrical shock PRECAUTIONS Do not use the air conditioner for purposes other than cooling or heating the room Such as drying clothes preserving foods keeping animals or cultivating vegetables Do not block the air intake or outlet vent Such actions causes lowered performance and irregular operation Do not insert any objects into these vents to avoid the danger of...

Page 2: ...the temperature uniform Adjust the airflow control direction to achieve the optimum uniformity in room temperature Make sure the doors and windows are closed Avoid opening doors and windows as much as possible to keep the cool air in the room Clean the air filter regularly Contaminated air filter reduce the airflow and lower cooling and dehumidifying capacity Clean at least once a month Avoid usin...

Page 3: ...he air filter 1 Main filter removal and cleaning see Fig 4 5 7 8 To remove the main filter hold the handle at the bottom and pull down see Fig 4 Remove the 2 purifying filter frames from the main filter see Fig 5 Rinse the main filter on both sides in lukewarm tape water and allow it to dry not in direct sunlight Attache the 2 purifying filter frames back to the main filter Reinstall it in the ope...

Page 4: ... control of the air conditioner the recommended elevation of the installation is 180 cm from the floor In addition make sure to maintain a minimum clearance of 15 cm from any wall floor or ceiling The wall opening should be suitable for enclosing a wooden frame for installation and fastening the unit Thus the location on the wall shall be carefully considered it must be free of any columns trusses...

Page 5: ...ot be left as in Fig 12 but should be chamfer outside to allow proper air movement as shown in Fig 13 IMPORTANT NOTE See Fig 12 and 13 1 Inside 2 Outside 3 Maximum wall thickness C 4 Lateral opening Fig 13 Remove the fresh air handle 1 Remove the 2 screws 4 located on the sides of the plastic front see Fig 14 Remove the plastic front pulling the bottom part and disengaging the upper part upward se...

Page 6: ...em to the cabinet with screws Set the supports tightly against the outside wall and tighten screws permanently Install the foam seal 3 enclosed with air conditioner between the frame and the cabinet providing a good seal between the interior and the exterior Install the drain as outlined in the section Drain Installation CABINET INSTALLATION IN WALL See Fig 17 1 Front panel 2 Cabinet 3 Foam seal 4...

Page 7: ... front the screws and the control knobs 2 Demonstrate operation of the air conditioner to the customer and explain all its functions 3 Explain filter removal cleaning and re installtion FINAL TASKS I n s t a l l a t i o n a n d M a i n t e n a n c e I n s t r u c t i o n s ROOM AIR CONDITIONER SERIES MAY The conditioner is to be installed according to all professional rules as well as the standard...

Reviews: