TROUBLESHOOTING
DCH DCI 41 Version - 1
Index1:
1:Indoor or Outdoor DC Fan Motor(control chip is in fan motor)
Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in fan motor
connector. If the value of the voltage is not in the range showing in below table, the PCB must has
problems and need to be replaced.
DC motor voltage input and output
NO.
Color
Signal
Voltage
1
Red
Vs/Vm
280V~380V
2
---
---
---
3
Black
GND
0V
4
White
Vcc
14-17.5V
5
Yellow
Vsp
0~5.6V
6
Blue
FG
14-17.5V
2.
Outdoor DC Fan Motor (control chip is in outdoor PCB)
Power on ,and check if the fan can run normally, if the fan can run normally, the PCB must has problems
and need to be replaced, If the fan can
’t run normally, measure the resistance of each two pins. If the
resistance is not equal to each other, the fan motor must have problems and need to be replaced,
otherwise the PCB must has problems and need to be replaced.
3. Indoor AC Fan Motor
Power on and set the unit running in fan mode at high fan speed. After running for 15 seconds,
measure the voltage of pin1 and pin2. If the value of the voltage is less than 100V(208~240V power
supply)or 50V(115V power supply), the PCB must has problems and need to be replaced.
Summary of Contents for JSP023054
Page 12: ...DIMENSION Version 1 12 DCH DCI For JOSI DCH009 N11 For JOSI DCH012 N11 For JOSI DCH018 N11 ...
Page 13: ...DIMENSION DCH DCI 13 Version 1 For JOSI DCH024 N11 ...
Page 18: ...WIRING DIAGRAM Version 1 18 DCH DCI 6 2 Model JOAU DCY009 H11 JOAU DCY012 H11 ...
Page 66: ...SERVICE MANUAL DCH DCI Series ...