Electrical Wiring
ON
OFF
Status of SW08-[6]
Controlling Method
Wired control( include one control to multiple units, two controls to one
unit and one control to one unit)
Remote control
1. Switches or jumper wire must be adjusted when the wire controller is powered off. If the wire
controller is powered on, the above operations will be invalid.
2. Function difference between master wire controller and slave one:
Master wire
controller
Slave wire controller
Function
All of functions
Only with below functions:
ON/OFF, MODE, FAN SPEED, SET TEMP., SWING
Contrastive
items
Note
How to change the function switches?
Factory Seting
ON
default setting
SW1-7
Factory Setting
OFF
default setting
SW1-8
No.
Type
State of switch
Function description
Select the master or
the slave controller
ON
set as the slave controller
OFF
SW1-1
OFF
set as the master controller
Select the controller
mode
ON
standard controller
SW1-2
air handler controller
Room temperature
display option
ON
visible room temperature
SW1-3
invisible room temperature
26
o
lock
ON
Unavailable 26
o
lock
SW1-4
available 26
o
lock
Temperature sensor
position option
ON
Sensor of the controller
SW1-5
Sensor in the unit
OFF
Auto restart
ON
unavailable
SW1-6
available
OFF
OFF
OFF