2-1
PRODUCT DATA SHEET
SM DEL60Hz 1-E.0 GB
2.
PRODUCT DATA SHEET
2.1
Delta 25 DCI / DCR 25 60Hz R410A
Model Indoor Unit
DELTA 25 DCI
Model Outdoor Unit
DCR 25 R410A
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Capacity (4)
Btu/hr
8530(3070-10920)
8530(3410-12620)
kW
2.5(0.9-3.2)
2.5(1.0-3.7)
Power input (4)
kW
0.73(0.35-1.15)
0.69(0.35-1.15)
EER (Cooling) or COP(Heating) (4)
W/W
3.41
3.61
Energy efficiency class
A
A
Power supply
V
220-240
Ph
1
Hz
60
Rated current
A
3.3
3.1
Power factor
0.97
0.97
Prated (IDU)
W
25
Prated (IDU+ODU)
W
1300
Starting current
A
10.5
Circuit breaker rating
A
10
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
H/M/L
RPM
1200/1050/850
Air flow (1)
H/M/L
m3/hr
420/350/270
External static pressure
Min
Pa
0
Sound power level (2)
H/M/L
dB(A)
54/50/47
Sound pressure level(3)
H/M/L
dB(A)
39/35/32
Moisture removal
l/hr
1.0
Condenstate drain tube I.D
mm
16
Dimensions
WxHxD
mm
680x250x185
Net Weight
kg
7
Package dimensions
WxHxD
mm
740x310x248
Packaged weight
kg
10
Units per pallet
units
32 units per pallet
Stacking height
units
8 levels
OUTDOOR
Refrigerant control
EEV
Compressor type,model
Rotary,Panasonic 5RS092XDJ01
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H
RPM
830
Air flow
H
m3/hr
1460
Sound power level
H
dB(A)
64
Sound pressure level(3)
H
dB(A)
54
Dimensions
WxHxD
mm
760x545x245
Net Weight
kg
36
Package dimensions
WxHxD
mm
880x610x310
Packaged weight
kg
39
Units per pallet
Units
12 units per pallet
Stacking height
units
3 levels
Refrigerant type
R410A
Scharg
kg(7.5m)
0.85
Additional charge
No need
Connections between units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
3/8"(9.53)
Max.tubing length
m.
Max.15
Max.height
difference
m.
Max. 10
Operation control type
Remote control
Heating elements (Option)
kW
Others
(1)
Airflow in ducted units; at nominal external static pressure.
(2)
Sound power in ducted units is measured at air discharge.
(3)
Sound pressure level measured at 1-meter distance from unit.
(4)
Rating conditions in accordance to ISO 5151 and ISO 13253 (for ducted units).