Electrical wiring and connections should be made
by
electricians in accordance with local
electrical codes and regulation. The air conditioner
units must be grounded.
The air conditioner units must be connected to an
adequate power outlet from a separate branch
circuit protected by a time delay circuit breaker, as
on unit's nameplate.
Voltage should not vary beyond ± 10% of the rated
voltage.
25A
2
40A
14.0kW
UNIT
2
3x20A
14.0kW
6. The cable between controller and indoor
unit shall be fixed accordingly to local
electrical requirements.
1PH Units Power upply to outdoor and indoor units
1PH Units Power upply to outdoor unit
1. Indoor Unit
2. Power Supplay Cable
3. Main Power Breaker
4. Outdoor Unit
5. Interconnecting Cable (2x0.75 mm2)**
6. Wireless Remote Control
7. Display Unit
8. Display Connector
9. Control Cable **
10. Sensor Wire with Connector
11. Room Temperature Sensor
12. Power Interconnecting Cable (3x1.5 mm
2
)**
13. Power Breaker (*by Installer)
* The Power Breaker must be of type that disconnect all poles with 3 mm contact opening.
** Use shielded cable and connect the shield to earth point
for indoor unit only
.
3x6mm
2
32A
14.0 kW
POWER SUPPLY
CABLE
CIRCUIT
BREAKER
NOMINAL
CAPACITY
POWER SUPPLY
SIDE
TO OUTDOOR
UNIT
230V / 50Hz / 1 PH
9
Optional