SPECIFICATION
HMF Series 10 Version - 1
Model Indoor Unit
AWSI-HMF018-N11
Model Outdoor Unit
AWAU-YMF018-H11
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Average
Capacity
(1)
kW
5.275
5.275
EER /COP
(2)
W/W
3.22
3.61
Energy efficiency class
A
A
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
16
INDO
O
R
Fan type & quantity
Cross flow fan x1
Fan speeds
H/M/L
RPM
1280/1100/800
1280/1100/950
Air flow
(3)
H/M/L
m3/hr
800/700/500
800/700/590
External static pressure
Min-Max
Pa
0
Sound power level
(4)
H/M/L
dB(A)
55
Sound pressure level
(5)
H/M/L
dB(A)
45/40/33
Moisture removal
l/hr
3
1.8
Condensate drain tube I.D
mm
16
16
Dimensions
WxHxD
mm
940 x275x205
Weight
kg
12
10
Package dimensions
LxWxH
mm
1015x265x350
Packaged weight
kg
15.5
12.5
Stacking height
units
8
O
UTDO
O
R
Refrigerant control
Capillary
Compressor type, model
ROTARY
ROTARY
Fan type & quantity
Axial x 1
Axial x 1
Fan speeds
H/L
RPM
890
Air flow
H/L
m3/hr
2300
Sound power level
(4)
H/L
dB(A)
70
Sound pressure level
(5)
H/L
dB(A)
60
Dimensions
WxHxD
mm
760x285x590
Weight
kg
44
36.5
Package dimensions
LxWxH
mm
887x355x645
Packaged weight
kg
46
39
Stacking height
Units
4
Refrigerant type
R410A
R410A
Refrigerant charge (standard connecting tubing length)
kg(5m)
1.6
1.15
Additional charge per 1 meter
gr / 1m
40
20
Connections between units
Liquid line
In.(mm)
1/4(6.35)
Suction line
In.(mm)
1/2"(12.7)
Max.tubing length
m.
25
Max.height difference
m.
10
Operation control type
Remote control
Remote control
Heating elements
kW
Others