EXPLODED VIEW & SPARE PART LIST

 

 

SM HHD 1-A.1 GB 

 

15-1 

15. 

EXPLODED VIEW & SPARE PART LIST 

15.1 

Exploded view of indoor unit:  HHD009 

 

 

E

V -

 A

W

S

I-

H

H

D

0

0

9

-N

1

1

Summary of Contents for AWAU-YHD009-H11

Page 1: ...Indoor Units Outdoor Units AWSI HHD009 N11 AWAU YHD009 H11 AWSI HHD012 N11 AWAU YHD012 H11 AWSI HHD018 N11 AWAU YHD018 H11 AWSI HHD024 N11 AWAU YHD024 H11 REFRIGERANT R410A HEAT PUMP SM HHD 1 A 1 GB...

Page 2: ...o changes in the relevant page All pages in the following list represent effected non effected pages divided by chapters Dates of issue for original and changed pages are Original 01 01 Aug 2017 Total...

Page 3: ...OUTLINE DIMENSION 4 1 5 PERFORMANCE DATA 5 1 6 PRESSURE CURVES 6 1 7 SOUND LEVEL CHARACTERISTICS 7 1 8 ELECTRICAL DATA 8 1 9 WIRING DIAGRAM 9 1 10 REFRIGERATION DIAGRAMS 10 1 11 TUBING CONNECTIONS 11...

Page 4: ...els Microprocessor control and indoor LED display High SEER SCOP A A level with Average climate Torque control for compressor running in lower Freqency but with low vibration and little sound Max allo...

Page 5: ...lytic Bi anti bacterial and observe bad gaseous and smokes 1 4 Control The microprocessor indoor controller and an infrared remote control supplied as standard provide complete operating function and...

Page 6: ...lease refer to the Product Data Sheet Chapter 2 It includes Compressor mounted in a soundproofed compartment Axial fan driven by DC motor Outdoor coil with hydrophilic louver fins for RC units Outlet...

Page 7: ...CTION 1 4 SM HHD 1 A 1 GB 1 8 Matching Table OUTDOOR UNITS INDOOR UNITS AWSI HHD009 N11 AWSI HHD012 N11 AWSI HHD018 N11 AWSI HHD024 N11 AWAU YHD009 H11 V AWAU YHD012 H11 V AWAU YHD018 H11 V AWAU YHD02...

Page 8: ...d pressure level 5 H M L VL dB A 24 30 38 41 Moisture removal l hr 0 80 Condensate drain tube I D mm 16 Dimensions WxHxD mm 770 283 201 Weight kg 8 Package dimensions WxHxD mm 847 276 345 Packaged wei...

Page 9: ...re level 5 H M L VL dB A 25 31 39 42 Moisture removal l hr 1 40 Condensate drain tube I D mm 16 Dimensions WxHxD mm 770 283 201 Weight kg 9 Package dimensions WxHxD mm 847 276 345 Packaged weight kg 1...

Page 10: ...l 5 H M L VL dB A 32 37 40 45 Moisture removal l hr 1 80 Condensate drain tube I D mm 16 Dimensions WxHxD mm 865 305 215 Weight kg 12 Package dimensions WxHxD mm 948 310 383 Packaged weight kg 15 Stac...

Page 11: ...vel 5 H M L VL dB A 34 42 47 51 Moisture removal l hr 2 00 Condensate drain tube I D mm 16 Dimensions WxHxD mm 1007 315 219 Weight kg 14 Package dimensions WxHxD mm 1076 328 398 Packaged weight kg 17...

Page 12: ...ts Cooling Indoor 27o C DB 19o C WB Outdoor 35 o C DB Heating Indoor 20o C DB Outdoor 7o C DB 6o C WB 3 1 Operating Limits R410A Indoor Outdoor Cooling Upper limit 32oC DB 23oC WB 43oC DB Lower limit...

Page 13: ...OUTLINE DIMENSION SM HHD 1 A 1 GB 4 1 4 OUTLINE DIMENSION 4 1 Indoor HHD009 HHD012 HHD018 HHD024 Models W H D HHD009 012 770 283 201 HHD018 867 305 215 HHD024 1008 319 221...

Page 14: ...OUTLINE DIMENSION 4 2 SM HHD 1 A 1 GB 4 2 Outdoor YHD009 YHD012 4 3 Outdoor YHD018...

Page 15: ...OUTLINE DIMENSION SM HHD 1 A 1 GB 4 3 4 4 Outdoor YHD024...

Page 16: ...PERFORMANCE DATA SM HHD 1 A 1 GB 5 1 5 PERFORMANCE DATA 5 1 Model HHD009 YHD009 HHD012 YHD012...

Page 17: ...PERFORMANE DATA 5 2 SM HHD 1 A 1 GB 5 2 Model HHD018 YHD018 HHD018 YHD018...

Page 18: ...PRESSURE CURVES SM HHD 1 A 1 GB 6 1 6 PRESSURE CURVES TBD...

Page 19: ...SOUND LEVEL CHARACTERISTICS SM HHD 1 A 1 GB 7 1 7 SOUND LEVEL CHARACTERISTICS 7 1 Sound Pressure Level...

Page 20: ...SOUND LEVEL CHARACTERISTICS 7 2 7 2 Soud Pressure Level Spectrum Measured as Figure 1 TBD...

Page 21: ...Current A 6 9A 7 3A 11 8A 12 4A Circuit Breaker A 10A 10A 16A 16A Power Supply Wiring No X Cross Section mm2 3x1 5 mm2 3x1 5 mm2 3x1 5 mm2 3x2 5 mm2 Interconnecting Cable Model No X Cross Section mm2...

Page 22: ...WIRING DIAGRAMS SM HHD 1 A 1 GB 9 1 9 WIRING DIAGRAM 9 1 HHD009 HHD012 9 2 HHD018 HHD024...

Page 23: ...WIRING DIAGRAM 9 2 SM HHD 1 A 1 GB 9 3 YHD009 YHD012 9 4 YHD018 YHD024...

Page 24: ...REFRIGERATION DIAGRAMS SM HHD 1 A 1 GB 10 1 10 REFRIGERATION DIAGRAMS 10 1 HHD009 YHD009 HHD012 YHD012 10 2 HHD018 YHD018 HHD024 YHD024...

Page 25: ...11 TUBING CONNECTIONS When the outdoor unit is installed above the indoor unit an oil trap is required every 5m along the suction line at the lowest point of the riser In case the indoor unit is inst...

Page 26: ...rse Cycle Heat Pump RCT Remote Control Temperature sensor RGT Return Gas Temperature sensor RPS Rounds per second mechanical speed RV Reverse Valve SB STBY Stand By SUCT Compressor Suction Temperature...

Page 27: ...d D value When the D value is small decrease the frequency When the D value is large increase the frequency 3 Frequency management when other controls are functioning When frequency is drooping Freque...

Page 28: ...Turbo button the super high fan speed is selected on Remote control and the indoor fan rotates at super high speed 12 1 5 Outdoor Fan Control 12 1 5 1OFAN Speed Type The outdoor fan motor is DC motor...

Page 29: ...the indoor fan will run at the setting speed If RAT SPT 2 the compressor will stop operation and the outdoor fan will delay 30 seconds to stop While the indoor fan will run at the setting speed If SP...

Page 30: ...air function will be activated and indoor fan operates according to following rules Case 1 RAT 24 o C When ICT 40 o C IFAN Stop for 2 min and then switch to low speed When ICT 40 o C IFAN Low for 1 m...

Page 31: ...Position L and D stop in any place between Position L and position D When the unit is turned off the air deflector will stay in position 0 The swing is available only when the swing function is set a...

Page 32: ...ording to RAT on the IDU I Feel function can not be remembered after power failure 12 11 Forced operation Refrigerant recovery Enter into Forced Operating After the unit is energized for 5mins press t...

Page 33: ...ature in 5s successively to enter into Forced deicing Heating indicator from display will blink ON 10s and OFF 0 5s to indicate the unit is under Forced deicing Exit Forced deicing Once the unit finsi...

Page 34: ...inal mode If the unit stops as such protection for 6 times it can not resume running automatically and display error code E2 it can resume by pressing ON OFF During the operating If compressor operate...

Page 35: ...n will be cleared 12 13 4 Outdoor Coil Overheating protection Cool Dry Mode During cooling operation the ODU Coil Overheating Protection is detected by temperature sensor OCT When OCT A o C compressor...

Page 36: ...finishing the deicing protection In the deicing protection IFAN is forced OFF 12 13 6 1 Deicing Starting Conditions This protection is for Heat Pump Only This protection is carried out by the cooling...

Page 37: ...3min continuously the unit will stop and will show communication malfunction protection E6 if the communication malfunction had been resumed and the compressor had stopped for a period of 3min the uni...

Page 38: ...rotection Protect the IPM modular by reducing compressor frequency or stop compressor according to the Module temperature HST When HST 80C compressor frequency will be decreased or stopped increasing...

Page 39: ...ing mode is displayed COOL INDICATOR DRY INDICATOR HEAT INDICATOR 1 Lights up during specified operation mode COOL DRY HEAT 2 HEAT indicator will blink ON 10s and OFF 0 5s under Deicing protection 2 7...

Page 40: ...the circuit parts without first turning off the power At time such as when the circuit board is to be replaced place the circuit board assembly in a vertical position Normally diagnose troubles accor...

Page 41: ...Coil Over Heating Protection E8 OPER Indicator OFF 3S and blink 8 times 1 Too high ambient temperature 2 Poor heat exchange including blockage and bad radiating environment EEPROM problem EE HEAT Ind...

Page 42: ...kage 3 OLP damaged IPM protection H5 HEAT Indicator OFF 3Sand blink5 times 1 Abnormal power input voltage 2 Compressor wiring mistake 3 Liquid and gas valve are not open 4 EEV damaged or not proper wo...

Page 43: ...pping for DC BUS U3 HEAT Indicator OFF 3Sand blink20 times Supply voltage is unstable AC Current detection problem U5 COOL Indicator OFF 3Sand blink13 times Outdoor main board damaged The RV is abnorm...

Page 44: ...ower LED is unlighted power down the system and check the fuse of the Indoor unit If the fuse is OK replace the Indoor unit controller If the fuse has blown replace the fuse and power up again Checkin...

Page 45: ...T R T chart 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Temperature C Resistance Kohm ICT OCT R T Chart 0 10 20 30 40 50 60 70 80 90 100 110...

Page 46: ...CTERISTICS OF SENSOR 14 2 SM HHD 1 A 1 GB 14 1 3 CTT CTT R T Chart 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Temperature C Resistance...

Page 47: ...EXPLODED VIEW SPARE PART LIST SM HHD 1 A 1 GB 15 1 15 EXPLODED VIEW SPARE PART LIST 15 1 Exploded view of indoor unit HHD009 EV AWSI HHD009 N11...

Page 48: ...Press Plate 1 15 10352423 Cross Flow Fan 1 16 01002957 Evaporator Assy 1 17 05212423 Temp Sensor Sleeving 1 18 24212108 Evaporator Support 1 19 76512210 Fan Bearing 1 20 76712032 Bearing Holder 1 21 1...

Page 49: ...EXPLODED VIEW SPARE PART LIST SM HHD 1 A 1 GB 15 3 15 3 Exploded view of indoor unit HHD012 EV AWSI HHD012 N11...

Page 50: ...ress Plate 1 15 10352423 Cross Flow Fan 1 16 01002958 Evaporator Assy 1 17 05212423 Temp Sensor Sleeving 1 18 24212108 Evaporator Support 1 19 76512210 Fan Bearing 1 20 76712032 Bearing Holder 1 21 10...

Page 51: ...EXPLODED VIEW SPARE PART LIST SM HHD 1 A 1 GB 15 5 15 5 Exploded view of indoor unit HHD018 EV AWSI HHD018 N11...

Page 52: ...ler 1 15 390000597 Temperature Sensor 1 16 390000451 Temperature Sensor 1 17 24212119 Evaporator Support 1 18 01002320 Evaporator Assy 1 19 01252484 Wall Mounting Frame 1 20 10352036 Cross Flow Fan 1...

Page 53: ...EXPLODED VIEW SPARE PART LIST SM HHD 1 A 1 GB 15 7 15 7 Exploded view of indoor unit HHD024 EV AWSI HHD024 N11...

Page 54: ...e 0 15 20012828 Front Panel Assy 1 16 27230004362 Front Panel 1 17 20012514 Front Case Assy 1 18 24252016 Screw Cover 3 19 15012098 Fan Motor 1 20 10512138 Guide Louver 1 21 10542036 Axile Bush 2 22 0...

Page 55: ...EXPLODED VIEW SPARE PART LIST SM HHD 1 A 1 GB 15 9 15 9 Exploded view of outdoor unit YHD009 YHD012 EV AWAU YHD012 H11...

Page 56: ...Chassis Sub assy 1 11 1501308506 Fan Motor 1 12 01253073 Top Cover Sub Assy 1 13 01703104 Motor Support 1 14 01163812 Condenser Assy 1 01100200141 Condenser Assy 1 15 01473009 Rear Grill 1 16 07133978...

Page 57: ...an 1 10 02803151P Chassis Sub assy 1 11 1501308506 Fan Motor 1 12 26233100 Small Handle 1 13 01253073 Top Cover Sub Assy 1 14 0170310401 Motor Support 1 15 01100200142 Condenser Assy 1 16 01473009 Rea...

Page 58: ...EXPLODED VIEW SPARE PART LIST 15 12 SM HHD 1 A 1 GB 15 12 Exploded view of outdoor unit YHD018 EV AWAU YHD018 H11...

Page 59: ...n Valve 0 12 none Electric expand valve fitting 0 13 01255005P Coping 1 14 01305093P Left Side Plate 1 15 20113003 Insulated Board Cover of Electric Box 1 16 10000100093 Electric Box Assy 1 17 4201019...

Page 60: ...EXPLODED VIEW SPARE PART LIST 15 14 SM HHD 1 A 1 GB 15 14 Exploded view of outdoor unit YHD024 EV AWAU YHD024 H11...

Page 61: ...t off Valve 1 15 01365435P Baffle Valve Support 1 16 0130504401P Right Side Plate 1 17 22245003 Valve Cover 1 18 26235001 Big Handle 1 2623500101 Big Handle 1 19 26115004 Wiring Clamp 1 20 01475013 Re...

Page 62: ...APPENDIX 16 SM HHD 1 A 1 GB APPENDIX...