NOTE
Installing the unit in any of the following places may lead to
malfunction:
The site contains mineral oils such as cutting lubricant
Seaside where the air contains much salt.
Hot spring area where corrosive gases exist, e.g., sulfide gas.
Factories where the power voltage fluctuates seriously.
The place with direct sunlight and other heat supplies. If
there’s no way to avoid these, please install a covering.
Place like kitchen where oil permeates.
Place where strong electromagnetic waves exist.
Place where flammable gases or materials exist.
Place where acid or alkali gases evaporate.
Consider sound emission
Noise levels could represent an inconvenience if installed in areas
that require extreme silence, example near bedrooms
Unit
190
300
Diameter
A
560
650
If installed in inclosed space
The unit must be located in a space >15m³, and must have
unrestricted air flow.
Make sure there is enough Installation space.
For optimal efficiency and serviceability, the following clearances
should be maintained:
400mm on the air inlet side;
400mm on the air outlet side;
600mm in the back;
600mm in the front.
Barriera
Functional spaces
Summary of Contents for AW-TDF Series
Page 90: ...Parts unit 190 Description...
Page 91: ...Parts unit 190 Description...
Page 92: ...Parts unit 190 Description...
Page 93: ...Parts unit 300 Description El ectr ical heate r...
Page 94: ...Parts unit 300 Description...
Page 95: ...Parts unit 300 Description...
Page 129: ......
Page 159: ......