![Airwallet PRO310 Installation Manual Download Page 12](http://html1.mh-extra.com/html/airwallet/pro310/pro310_installation-manual_2879824012.webp)
Step Three
Installing the Airwallet PRO
See the table below for wire spec
ificati
ons. The schematic for the product can be found on page 19.
Wire
Number
Internal
Port
Number
Name
Description
No. 1
White
11
ACL
- Power supply
100-240VAC
No. 2
White
12
ACN
- Power supply
100-240VAC
No. 3
White
2
Input start signal
- CO
Supply start signal.
Max. 220 VDC; Max. 250 VAC;
Max. 60W
No. 4
White
3
Output start
signal - NO
For high start signal.
No. 5
White
10
(Optional) AC
input machine
busy signal*
AC input 100-240VAC - Line
NB: Is the busy signal neutral and can’t be
modified to line, then switch line/neutral
power supply to the Airwallet PRO.
No. 6
White
6
(Optional) DC
input machine
busy signal*
The DC input has to be within the
24VDC +- 2.4V
No. 7
White
1
Output start
signal - NC
For low start signal.
Not wired
out
5
Input GND
For 24V DC circuit as GND reference.
Not wired
out
7
Output 24V DC
supply
For 24V DC busy signal circuit
Not wired
out
8
Input 24V DC
24V power supply input
*Busy signal options: page 13