6/9
Quick Start Guide
Ulysses 8116
16x Analog Output
To download the latest version of Studio Matrix Designer, the Windows application
that controls all Studio Matrix hardware, go to: www.airtoolsaudio.com
TM
Symetrix
Engineered by
Redundant Operation
The following tables describes the possible failure modes and how they are handled with and without a redundant hardware pair.
Failure Handling with Redundant Pair
Failure
Action
Indications
Power Supply Failure
Switch to secondary unit Failed unit’s status light = flashing red and unit is offline
*
Fan Failure
Switch to secondary unit Failed unit’s status light = blipping red and unit is inactive
DSP Failure (crash or hardware prob-
lem)
Switch to secondary unit Failed unit’s status light = flashing red and unit is offline
*
FPGA Failure
Switch to secondary unit Failed unit’s status light = flashing red and unit is offline
*
Watchdog timeout (software hang)
Switch to secondary unit Failed unit’s status light = flashing red and unit is offline
*
Running factory code (boot mode switch
activated, upgrading firmware or failed
firmware upgrade)
Switch to secondary unit Failed unit’s status light = blipping red and unit is inactive
Problem with previous boot (crashed and
didn’t power down normally last boot)
Switch to secondary unit Failed unit’s status light = blipping red and unit is inactive
*
unit will light status light to indicate fatal failure as long as the nature of the failure allows it to do so
Failure Handling without Redundant Pair
Failure
Action
Indications
Power Supply Failure
Go offline
Status light = flashing red and unit is offline
*
Fan Failure
Indicate non-fatal error
Status light = solid red and unit is active
DSP Failure (crash or hardware problem) Go offline
Status light = flashing red and unit is offline
*
FPGA Failure
Go offline
Status light = flashing red and unit is offline
*
Watchdog timeout (software hang)
Go offline
Status light = flashing red and unit is offline
*
Running factory code (boot mode switch
activated, upgrading firmware or failed
firmware upgrade)
Indicate non-fatal error
Status light = solid red and unit is active
Problem with previous boot (crashed and
didn’t power down normally last boot)
Indicate non-fatal error
Status light = solid red and unit is active
*
unit will light status light to indicate fatal failure as long as the nature of the failure allows it to do so
Redundant Operation