added through the Dashboard and are awaiting 

confirmation to be added to the company. Simply tap 

on the monitors in this section to confirm adding them 

to the company. Monitors under section 2 are those 

which have been added to the company and are in 

Bluetooth range and can be connected to. Monitors 

under section 3 are those which are registered to the 

company and have datasets cached on the mobile 

device, but are not nearby. These cached datasets can 

still be accessed to generate a report even when the 

monitor is not in range. 

Please note that this is cached 

data only and does not allow for live, remote access to 

the monitor. 

Monitors under section 4 are nearby and 

are not accessible, either because they have not been 

added to the company yet through the Dashboard, or 

because they are registered to another company.

The proper monitor can be identified by the serial 

number on the monitor, which is also listed in the 

app. Additionally, the monitor can be identified by a 

custom nickname assigned to the monitor through 

the Dashboard. The monitor will beep once, and the 

blue light will flash once to confirm the connection and 

help you identify that you are connecting to the correct 

monitor. The app will begin transferring the dataset 

information from the monitor to the mobile device. 

Recent datasets are stored locally on the mobile device.

INITIATING A RADON TEST

Corentium Pro, like all radon testing devices, must be 

placed and used in accordance with all radon testing 

protocols required by the jurisdiction where the radon 

test is taking place.

Note: 

This information is not exhaustive, and does not 

contain any protocol or requirements for placement of 

the monitor. Please become familiar with, and comply 

with all regulations and requirements of your jurisdiction.

Scheduling a Radon Test

To start a radon test, connect to a monitor as described 

in the Connecting to Corentium Pro section. If the 

monitor is available to use for a radon test, a green 

button that says “Start Test” will be seen at the bottom 

of the screen, tap on this button to begin the scheduling 

process. You will be prompted to enter some mandatory 

information while the rest are optional.

Airthings recommends a minimum 48-hour 

measurement duration and 4 hours delay for all short-

term radon tests. Radon tests should terminate in 

24-hour increments to better account for day-to-night 

fluctuations of indoor radon concentrations.

Once all information about the property has been 

entered in the various fields spread across several 

pages, as indicated at the top of the screen, tap the 

Start

” button at the bottom of the last scheduling 

page. The monitor will beep, and the lights will flash for 

approximately 45 seconds as the monitor reboots and 

performs self-tests. The monitor will beep again, and if 

a delay was used, the green light will flash rapidly, once 

per second, to indicate that the radon test has been 

successfully scheduled. If no delay was scheduled the 

green light will flash once every 5 seconds to indicate 

that the monitor is currently recording information.

CONCLUDING A RADON TEST

Finalizing a Dataset

Once a radon test is complete, connect to the monitor. 

After the datasets have loaded, locate the proper 

dataset and tap on “

Finalize Dataset

”, here you can 

add any photos to the dataset, such as a building 

footprint diagram, or a photo showing that the 

monitor was indeed placed at the property. You can 

also add comments about deviations from protocol, 

such as the monitor being moved, or if it could not be 

placed according to protocol, and the reason for this 

placement. Additionally, you can add comments about 

temporary conditions, such as extreme weather which 

may have affected the measurement, or temporary 

radon reduction measures in place.

Once the photos and comments are added, or if you 

Summary of Contents for Corentium Pro

Page 1: ...f fresh air A Reset button B Kensington Security Slot C Mini USB connection There is no ON OFF button 1 Communication status light 2 Status lights LEDs 3 Battery compartment 4 Tripod mount 5 Serial number label 6 Calibration label A B C 1 3 4 5 6 2 ...

Page 2: ... kPa 1 kPa Memory The internal memory stores 5 years of hourly datapoints Memory Capacity 1 900 days of measurements 5 datasets of one year length 177 datasets of 1 week length 325 datasets of 2 day length Memory Type Non volatile flash memory SPECIFICATIONS USAGE USAGE SAFETY The radon sensors in Corentium Pro are made for inside use only Avoid storing or using the monitor in environments with hi...

Page 3: ...ection CREATING AN AIRTHINGS ACCOUNT In order to use the mobile app and online Pro Dashboard a user must create an Airthings account by visiting the website at pro airthings com and clicking on the Sign Up with Airthings button Follow the remaining prompts to create an account USING THE ONLINE PRO DASHBOARD Radon tests are uploaded from the mobile app to the Dashboard and can be accessed from any ...

Page 4: ...ready for use click on Publish You may also use the duplicate feature to create additional templates Generating a Report in the Dashboard Once a radon test dataset has been uploaded to the Dashboard it can be accessed by clicking on the datasets icon in the left menu A list of all datasets in the Dashboard is presented and a specific dataset can be located using the search field To generate a repo...

Page 5: ...adon Test To start a radon test connect to a monitor as described in the Connecting to Corentium Pro section If the monitor is available to use for a radon test a green button that says Start Test will be seen at the bottom of the screen tap on this button to begin the scheduling process You will be prompted to enter some mandatory information while the rest are optional Airthings recommends a min...

Page 6: ...ersion date and time calibration expiration date or status of a monitor connect to it as described in the section above Once connected to the monitor tap on the i button near the serial number at the top of the screen Other Operations To log out of the app from the home screen tap on the gear icon at the top right corner of the screen then tap on Log Out You can also get help with the Corentium Pr...

Page 7: ...rsuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residual installation This equipment generates uses and can radiate frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in ...

Page 8: ... We are here to help help airthings com Manuel d utilisation disponible en ligne Manual del usuario disponible online Manuale d istruzioni disponibile online Breathe better Live better help airthings com pro The manual is available in other languages online at ...

Reviews: