. Protection function

1

Automatic defrost protection function

The dehumidifier will defrost automatically when it frost on a
certain level on the evaporator, compressor shutdown. The
dehumididifer will start automatically when defrosting
finished. We set the machine defrost when ambient
temperature is under 18

.

2

Compressor delay start protection function

If you want to start the machine in 3 minutes after
shutdown dehumidifier, the compressor will start after 3
minutes for delay protection.

Summary of Contents for DDA-480

Page 1: ...Thank you for buying Dehumidifier Please read the instruction carefully in order to use the machine safety and properly And please keep this instruction safety for the time you need it Instruction For...

Page 2: ...y instructions 2 Structure of Product 3 Installation Sketch 5 Control Panel 6 Protection function 9 Caution in use 10 Common Faults Removing 11 Maintenance of Machine 12 Technical Parameters 13 Perfor...

Page 3: ...efore cleaning or maintain the machine Don t use in arrow and sealed space make sure to connect the ground lead Don t do any change of machine unless guiding by our technicians Attention The machine h...

Page 4: ...5 Structure of Product Outer structure Inner structure...

Page 5: ...5 Sketch of the shell Make sure suitable space to install the machine...

Page 6: ...6 Installation Sketch Attention Install the machine stably with screw suspender on the ceiling and make sure there have over 2 degree slant angle to the drainage tube for smooth continuously drain...

Page 7: ...or ventilation mode the screen will display corresponding icon 4 In the dehumidifying mode Press Setting once to set target humidity Press Setting twice to set timed on hours Press Setting thrice to...

Page 8: ...in timed on off or clock setting mode 7 Humidity display Current ambient humidity display when in standby ventilation dehumidifying mode Blinking when at humidity setting mode 8 Guiding light Blinking...

Page 9: ...humidity 4 Time set press the setting key into timed on setting mode on light blinking press or to set hours and minutes up or down Press the setting key again into timed off setting mode off light bl...

Page 10: ...evaporator compressor shutdown The dehumididifer will start automatically when defrosting finished We set the machine defrost when ambient temperature is under 18 2 Compressor delay start protection...

Page 11: ...to seal environment better to increase the effect of dehumidifier Do not place the machine in the area which may come into contact with water or chemical Do not use any relay extension line or adapte...

Page 12: ...losed Close doors and windows and vents Refrigerant leakage Contact for maintenance Cannot reach suitable humidity level after long time running Doors and windows are not closed Close doors and window...

Page 13: ...th moistened with a little diluted neutral detergent Regular maintenance Filter Cleaning it will affect the dehumidifying effect or cause malfunction if accumulate dust on filter it needs to be cleane...

Page 14: ...000 m h Applying area 2 6m floor height 280 350 Refrigerant R407c 2 2Kg Nominal dehumidification 480 liters per day 32 RH90 Working temperature 5 38 C Gross weight 260 kgs Net Weight 240 kgs Overall d...

Page 15: ...ifier 2 One Instructions For user Dehumidfying Capacity at Different Ambient Temperatuer and Humidity Conditions T RH 10 10 15 15 20 20 30 30 32 32 60 80 60 80 60 80 60 80 60 90 DDA 480 75 100 106 144...

Page 16: ...AIRTECHNIC CHATZOUDIS E P E Add MICHAIL KARAOLI 19 NEA CHALKIDONA 14343 ATHENS GREECE TEL 30 211 7055500 30 210 2130051 Fax 30 210 2223283 Http airtechnic gr...