AirTech AQ-40B User Manual Download Page 6

can be configured for several different types of decode 
operation. If a channel is selected that has Selcall 
activated the radio will be muted until the proper signal is 
received. When this occurs the radio can sound a ringing 
type alert signal or a voice message maybe heard. 
Depending upon the initial programming, pressing the 
PTT may cause an automatic identifier to be sent. When 
programmed for Selcall pressing the monitor and function 
buttons at the same time can cause the Selcall mode to 
be cancelled and generate an automatic identification. 
Please have your radio technician or dispatcher fully 
explain this operation.  
 

Charger and Battery 

1. Battery (Ni-Mh) 

Voltage & Current 

DC 7.5V , 1650mA 

Duty time (5-5-90) 

Over 8 hrs 

2. Charger 

Input power 

 

CHARGER INPUT DA 12V

(120VAC)ADAPTOR 
INPUT POWER

 

Operating temperature 

10-30 deg. C 

 
Connect the charger to an appropriate outlet (120VAC 
ADAPOR). Turn the transceiver power off and place the radio 
into the front socket of the charger. The red light illuminates 
during charging and the green light comes on when the 
charge is complete. When you place two batteries in the 
charger at the same time, the front battery will charge first. 
The rear battery will begin charging when the front battery 
charge is complete. 

On Charging 

Red 

Blinking Abnormal 

battery 

Green On 

Fully 

charged 

On 

Stand-by for charging (rear cup) 

Orange 

Blinking Discharging 

 

z

  When you put a battery in the rear cup of the charger the 

charger checks the voltage. If voltage is over 7.4V, the 
charger starts discharging for 4 minutes then checks 
again. If voltage is still more than 7V, it discharges until 
the voltage is 6V then starts charging. 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 

8

 