AirStage UTY-DCGG Installation Manual Download Page 1

中 文

安装说明书

安装说明书

中央控制器

仅针对授权的专业维修人员。

Türkçe

MONTAJ KILAVUZU

MERKEZI UZAKTAN KUMANDA

Yaln

ı

zca yetkili servis personeli için.

Ру

сский

РУКОВОДСТВО

 

ПО

 

УСТАНОВКЕ

ЦЕНТРАЛЬНЫЙ

 

ДИСТАНЦИОННЫЙ

 

КОНТРОЛЛЕР

Только

 

для

 

авторизованного

 

обслуживающего

 

персонала

.

Português

MANUAL DE INSTALAÇÃO

CONTROLE REMOTO CENTRAL

Apenas para técnicos autorizados.

E

λλη

vIk

ά

ΕΓΧΕΙΡΙΔΙΟ

 

ΕΓΚΑΤΑΣΤΑΣΗΣ

ΚΕΝΤΡΙΚΌ

 

ΤΗΛΕΧΕΙΡΙΣΤΉΡΙΟ

Μόνο

 

για

 

εξουσιοδοτημένο

 

τεχνικό

 

προσωπικό

.

Italiano

MANUALE DI INSTALLAZIONE

TELECOMANDO CENTRALE

A uso esclusivo del personale tecnico autorizzato.

Español

MANUAL DE INSTALACIÓN

CONTROLADOR REMOTO CENTRAL

Únicamente para personal de servicio autorizado.

Français

MANUEL D’INSTALLATION

TÉLÉCOMMANDE CENTRALE

Pour le personnel agréé uniquement.

Deutsch

INSTALLATIONSANLEITUNG

ZENTRALE FERNBEDIENUNG

Nur für autorisiertes Fachpersonal.

English

INSTALLATION MANUAL

CENTRAL REMOTE CONTROLLER

For authorized service personnel only.

PART NO. 9378379053-03

[Original instructions]

UTY-DCGY

UTY-DCGG

Summary of Contents for UTY-DCGG

Page 1: ...ΡΙΟ Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό Italiano MANUALE DI INSTALLAZIONE TELECOMANDO CENTRALE A uso esclusivo del personale tecnico autorizzato Español MANUAL DE INSTALACIÓN CONTROLADOR REMOTO CENTRAL Únicamente para personal de servicio autorizado Français MANUEL D INSTALLATION TÉLÉCOMMANDE CENTRALE Pour le personnel agréé uniquement Deutsch INSTALLATIONSANLEITUNG ZENTRALE FERNBEDIENUNG N...

Page 2: ...If gas leaks and settles around the unit it can cause a fire Do not use the unit for special purposes such as storing food raising animals growing plants or preserving precision devices or art objects It can degrade the quality of the preserved or stored objects Install the unit in a well ventilated place avoiding rains and direct sunlight Do not operate this unit when your hands are wet Touching ...

Page 3: ...9 3 29 32 84 3 5 16 135 5 5 16 2 Ø5 3 32 3 16 3 16 5 1 17 32 7 8 67 2 5 8 R2 5 39 2 Installation restrictions 4 2 Make a service space to per form installation work Unit mm in 150 5 15 16 Service space WIRING RULES 5 WARNING Always use the accessories and specified installation work parts Check the state of the installation parts Not using the specified parts will cause fall water leakage electric...

Page 4: ... will cause trouble heating fire or electric shock Install the indoor and outdoor units power supply cable transmis sion cable and remote controller cable 1m 40 in away from televi sion and radio to avoid distorted images and noise Otherwise a malfunction could result Perform wiring so that water does not enter this unit along the external wiring Always install a trap to the wiring or take other c...

Page 5: ... with a flat blade screwdriver and 2 separate the front panel and rear panel Front panel Rear panel Screwdriver Claws Disconnect the connection cable connector from the connector 3 CN13 of the front panel PC board Rear panel Front panel CN13 Connection cable Power supply unit 6 2 2 Remove the screws 4pcs 1 Remove the cover 2 cover DIP Switch Setting 6 3 CAUTION Use an insulated screwdriver to set ...

Page 6: ...touch bush accessories Connection cable accessory Relay connector knockout knockout Hole B Hole A Hole C Pass 5 Connection cable accessory through Hole C and Hole D and connect it to rear panel terminal Pass transmission cable through Hole B Hole C and Hole D 6 and connect it to rear panel terminal Fix with the cable tie ac cessory Hole B Cable tie accessory Hole A Hole C Hole D Connection cable a...

Page 7: ...r supply unit PC board Fix with 2 cable tie firmly POWER SUPPLY L N L N Hole A POWER SUPPLY Cable tie accessory Power supply cable Open the knockout of hole B section and install the one touch 3 bush Pass the extension cable 4 service parts through Hold B and connect it to the relay connector coming from the power supply unit Fix with 5 cable tie firmly POWER SUPPLY L N One touch bush accessory Re...

Page 8: ...uit detection resistance R ON 500 ohm 1 Open circuit detection resistance R OFF 100 kilo ohm A twisted pair cable 0 33mm 2 22AWG should be used Maxi mum length of cable is 25 m 82ft Input Method Terminal Input signal Operation Edge CN6 Low High Emergency stop or All On High Low Emergency stop reset or All Off Pulse CN6 Low High Emergency stop or All On CN7 Low High Emergency stop reset or All Off ...

Page 9: ...ut output function the connection cable is drawn out as shown in the figure below Fix the connection cable securely using the cable tie Ex 1 When the cable is drawn out from the top of this unit Cutting out Connection cable Cable tie Ex 2 When the cable is drawn out from the back of this unit TURNING ON THE POWER 7 CAUTION Check that the power supply voltage is within the specified range If a powe...

Reviews: