En-3

PREPARATION

OPERATION

 It is possible to make the operation settings for all indoor units or individual units.

Hold down the PROGRAM (CLOCK ADJUST) button for
2 seconds or more.

2

Press the DAY button and select the
current day.
A

 appears around the selected

day.

Press the Set Time buttons to set the current time.
Press repeatedly to adjust the current time in 1-minute increments. Press and
hold to adjust the current time in 10-minute increments.
* Hold down a Set Time button to adjust the time quickly.

ex. Monday 10:00 (12-hour display)

Press again the PROGRAM (CLOCK
ADJUST) button to end.

CLOCK ADJUST

1

3

4

To set the current day and time

CLOCK ADJUST

DAY

 S          M          T          W         T         F         S

SUN

MON

TUE

WED

THU

FRI

SAT

Decrement Increment

To select the indoor unit

Press the Select button to select the indoor unit.

1st indoor unit

2nd indoor unit

8th indoor unit

All indoor units

The

 for the selected indoor unit lights, and the operating status is displayed.

* If all indoor units are selected, all of the registered indoor units are controlled at the same time.
* If all indoor units are selected, 

 appears on the Timer and Clock Display.

To set the operation mode

Press the Mode button to set the operation mode.

● 

Operation mode setting

Temperature setting range

AUTO ............................................................ 18 to 30 °C (64 to 88 °F)
COOL/DRY .................................................... 18 to 30 °C (64 to 88 °F)
HEAT ............................................................. 10 to 30 °C (48 to 88 °F)
The set temperature cannot be set during the FAN mode.
(The temperature will not appear on the remote controller’s display.)

Raise

Press the Set Temperature buttons to set the room temperature.

● 

Room temperature setting

* AUTO cannot be selected for a heat pump model unless it is set up as an Administrative indoor unit.
** FAN cannot be selected for a heat pump model.
*** HEAT cannot be selected for a cooling only model.
Refer to details in the Administrative indoor unit OPERATING TIPS.
* If the priority mode is set to “Priority on Control Indoor Unit”, the operating mode of

other indoor units except Control Indoor Unit will be controlled by a Control Indoor Unit.

* If the operating mode of Administrative Indoor Unit is set to “AUTO”, “AUTO” is

displayed in addition to the display of current operating mode on other wired remote
controllers except Administrative Indoor Unit. In this case, operation of other indoor
units is controlled by the Administrative Indoor Unit.

Example: When operating mode of the Adminis-

trative Indoor Unit is set to “AUTO” while
air conditioning setting. (The indication
on other wired remote controllers except
Administrative Control Indoor Unit).

Lower

* According to the initial setting, the heating temperature range from 10 to 15 °C (48

to 58 °F) cannot be set. In addition, the temperature range from 10 to 15 °C  (48 to
58 °F) is invalid depending on the model even if it can be set.

*

**

***

AUTO

COOL

DRY

FAN

HEAT

When Administra-
tive Indoor Unit is
set to “AUTO”.

Summary of Contents for UTY-CGG

Page 1: ...FUNCIONAMIENTO MANUALE DI ISTRUZIONI MANUAL DE INSTRU ES KEEP THIS MANUAL FOR FUTURE REFERENCE DIESE ANLEITUNG BITTE SORGF LTIG AUFBEWAHREN CONSERVEZ CE MODE D EMPLOI AFIN DE POUVOIR VOUS Y R F RER UL...

Page 2: ...l for repairs When moving consult authorized service personnel for disconnection and installation of this unit Do not touch with wet hands It may cause an electric shock If children may approach the u...

Page 3: ...ton Set Temperature Button Child Lock Function Timer and Clock Display and setting Displaying the Status and Controlling indoor units Indoor Unit Operation Indicators This shows the operating status a...

Page 4: ...o 88 F HEAT 10 to 30 C 48 to 88 F The set temperature cannot be set during the FAN mode The temperature will not appear on the remote controller s display Raise Press the Set Temperature buttons to se...

Page 5: ...rwise you will en ter the time setting mode 2 Press the Select button to select the indoor unit If all indoor units are selected the times for all of the registered indoor unit timers are set at once...

Page 6: ...ing the ENTER button without any operation setting because the time that is set will be cancelled To delete the operating time WEEKLY TIMER Timer setting AM 8 When the operating time is set the mark a...

Page 7: ...ONS WEIGHT HEIGHT WIDTH DEPTH WEIGHT UTY CGG DC 12 V 120 mm 4 3 4 in 120 mm 4 3 4 in 17 mm 5 8 in 160 g 0 35 lbs MONITOR MODE The operation status of each indoor unit can be checked in the Monitor mod...

Page 8: ......

Reviews: