CAUTION
Do not use the unit for special purposes, such as storing food, raising animals,
growing plants, or preserving precision devices or art objects.
It can degrade the quality of the preserved or stored objects.
Do not install where there is the danger of combustible gas leakage.
Do not install the unit near a source of heat, steam, or
fl
ammable gas.
Install the unit where drainage does not cause any trouble.
Install the indoor unit, power supply cable, transmission cable, and remote controller
cable at least 40 in. (1 m) away from a television or radio receivers. The purpose of
this is to prevent TV reception interference or radio noise.
(Even if they are installed more than 40 in. (1 m) apart, you could still receive noise
under some signal conditions.)
If children under 10 years old may approach the unit, take preventive measures so
that they cannot reach the unit.
Decide the mounting position with the customer as follows:
(1) Install the indoor unit on a place having a suf
fi
cient strength so that it withstands
against the weight of the indoor unit.
(2) The inlet and outlet ports should not be obstructed; the air should be able to blow all
over the room.
(3) Leave the space required to service the air conditioner.
(4) A place from where the air can be distributed evenly throughout the room by the unit.
(5) Install the unit where connection to the outdoor unit (or RB unit) is easy.
(6) Install the unit where the connection pipe can be easily installed.
(7) Install the unit where the drain pipe can be easily installed.
(8) Install the unit where noise and vibrations are not ampli
fi
ed.
(9) Take servicing, etc., into consideration and leave the spaces. Also install the unit
where the
fi
lter can be removed.
3.2. Installation dimensions
Ceiling height is as shown in the
fi
gure.
Strong and durable ceiling
11 in. (256 mm) or more (AUUB 18/24)
12 in. (298 mm) or more (AUUB 30/36)
60 in. (1,500 mm) or more
119 in. (3,000 mm) or more
71 in. (1,800 mm) to H
40 in. (1,000 mm) or more
Floor
Obstruction
H: Maximum height from
fl
oor to ceiling
Function setting
H [in. (mm)]
AUUB18
AUUB24
AUUB30
AUUB36
Standard mode
118 (3,000)
118 (3,000)
125 (3,200)
125 (3,200)
High Ceiling mode
137 (3,500)
137 (3,500)
141 (3,600)
165 (4,200)
* Be sure to make the function settings with the remote controller according to the
installed ceiling height.
Discharge Direction Setting
• The discharge direction can be selected as shown below.
4 DIRECTION
3 DIRECTION
4 in.(100 mm) or more
* Select the most appropriate air
fl
ow direction from 3 or 4 directions according to the
shape of the room and the installation position.
* When changing the number of outlets, we recommend using the optional AIR
OUTLET SHUTTER PLATE KIT to close the outlet.
* For the speci
fi
c closing pattern, please refer to the attached AIR OUTLET SHUTTER
PLATE KIT’S MANUAL. (Do so before installing the cassette grille as it will be
installed on the body.)
3.3. Installing the unit
WARNING
Install the air conditioner in a location which can withstand a load of at least 5 times
the weight of the main unit and which will not amplify sound or vibration. If the
installation location is not strong enough, the indoor unit may fall and cause injuries.
If the job is done with the panel frame only, there is a risk that the unit will come
loose. Please take care.
3.3.1. Position the ceiling hole and hanging bolts
(1) Positions of the ceiling opening, hanging bolt pitch, piping and ducts.
• Ceiling opening and hanging bolt pitch.
Unit: in. (mm)
37-3/8 (950) (Cassette grille)
33-1/16 (840) (Indoor unit)
31-5/16 (795) (Hanging bolt pitch)
5-1/8 (130)
7-7/8 (200)
1-15/16 (50)
13/16 to
1-3/4
(20 to 45)
13/16 to
1-3/4
(20 to 45)
13/16 to
1-3/4
(20 to 45)
13/16 to
1-3/4
(20 to 45)
37-3/8 (950) (Cassette grille)
33-1/16 (840) (Indoor unit)
5-1/8 (130)
3-1/8 (80)
5-1/8 (130)
33-7/8 to 35-13/16 (860 to 910)
(Ceiling opening)
27-1/2 (699)
(Hanging bolt pitch)
33-7/8 to 35-13/16 (860 to 910)
(Ceiling opening)
1-15/16 to 3-15/16 (50 to 100)
5-1/2 to 5-1
1/16
(140 to 145)
3/8 (10)
B
A
1-9/16 (40)
Model
A
B
AUUB 18/24
9-11/16 (246)
10-1/16 (256)
AUUB 30/36
11-5/16 (288)
11-3/4 (298)
• Refrigerant piping and drain piping positions.
3-1
/8 (80)
3/8 (1
0)
Gas pipe
Liquid pipe
Drain pipe
Unit: in. (mm)
Drain pipe
(Connect the attached
drain hose)
7-1
/1
6 (1
80)
5-1
/2 (1
40)
7-7/8
(200)
10-15/16 (278)
2-3/8 (60)
14-1/8 (358)
9371022314-03_IM.indb Sec1:3
9371022314-03_IM.indb Sec1:3
10/23/2013 2:59:32 PM
10/23/2013 2:59:32 PM