En-2

2.3. Accessories

 

WARNING

  For installation purposes, be sure to use the parts supplied by the manufacturer or 

other prescribed parts. The use of non-prescribed parts can cause serious accidents 
such as the unit falling, water leakage, electric shock, or 

fi

 re.

  The following installation parts are furnished. Use them as required.

  Keep the Installation Manual in a safe place and do not discard any other accessories 

until the installation work has been completed.

Name and Shape

Q’ty

Application

Operating Manual

1

Installation Manual

1

(This book)

Drain hose

1

For installing drain pipe
VP25 (O.D.32, I.D.25)

Hose Band

1

For installing drain hose

Drain hose insulation

1

Adhesive type 
(220 × 100 mm)

VT wire

1

For 

fi

 xing the drain hose L 280 mm

Coupler heat insulation
(Large)

2

For indoor side pipe joint (Gas pipe)

Coupler heat insulation
(Small) 

1

For indoor side pipe 
joint (Liquid pipe)

Cable tie (Extra large)

4

For 

fi

 xing the coupler

heat insulation

Cable tie (Large) 

2

Cable tie (Medium) 

2

For power supply and 
transmission and remote 
controller cable binding

Special nut A

(Large 

fl

 ange)

4

For installing indoor unit

Special nut B

(Small 

fl

 ange)

4

For installing indoor unit

Installation

template

1

For positioning the indoor unit

Auxiliary pipe assembly

1

For connecting the piping

]

2.4. Optional parts

The following options are available.

Description

Model No.

Application

Drain pump unit

UTR-DPB24T
9050642000

Round duct

UTD-RF204
9093160004

External output wire

9379529013

For output port

External input wire D

9368779016

For control input port
(Apply voltage terminal)

External input wire F

9368779023

For control input port
(Dry contact terminal)

External input wire B

9368778002

For forced thermostat off port
(Apply voltage terminal)

External input wire E

9368778019

For forced thermostat off port
(Dry contact terminal)

External input (no voltage) wire

9368779009

For control input port

3. INSTALLATION WORK

Correct initial installation location is important because it is dif

fi

 cult to move unit after it is 

installed.

]1

3.1. Selecting an installation location

Decide the mounting position together with the customer as follows.

 

WARNING

  Select installation locations that can properly support the weight of the indoor unit. 

Install the units securely so that they do not topple or fall.

 

CAUTION

  Do not install the indoor unit in the following areas:

• Area with high salt content, such as at the seaside. It will deteriorate metal parts, 

causing the parts to fail or the unit to leak water.

• Area 

fi

 lled with mineral oil or containing a large amount of splashed oil or steam, 

such as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the unit 
to leak water. 

• Area that generates substances that adversely affect the equipment, such as sulfuric 

gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed joints to 
corrode, which can cause refrigerant leakage. 

• Area that can cause combustible gas to leak, contains suspended carbon 

fi

 bers or 

fl

 ammable dust, or volatile in

fl

 ammables such as paint thinner or gasoline. If gas 

leaks and settles around the unit, it can cause a 

fi

 re.

• Area where animals may urinate on the unit or ammonia may be generated.

  Do not use the unit for special purposes, such as storing food, raising animals, 

growing plants, or preserving precision devices or art objects.

  It can degrade the quality of the preserved or stored objects.

  Do not install where there is the danger of combustible gas leakage.

  Do not install the unit near a source of heat, steam, or 

fl

 ammable gas.

  Install the unit where drainage does not cause any trouble.

  Install the indoor unit, power supply cable, transmission cable, and remote controller 

cable at least 1 m away from a television or radio receivers. The purpose of this is to 
prevent TV reception interference or radio noise. (Even if they are installed more than 
1 m apart, you could still receive noise under some signal conditions.)

  If children under 10 years old may approach the unit, take preventive measures so that 

they cannot reach the unit.

  Take precautions to prevent the unit from falling.

(1)  Install the indoor unit on a place having a sufficient strength so that it withstands 

against the weight of the indoor unit.

(2)  The inlet and outlet ports should not be obstructed; the air should be able to blow all 

over the room.

(3)  Leave the space required to service the air conditioner.
(4)  Install the unit where connection to the outdoor unit (or RB unit) is easy. 
(5)  Install the unit where the connection pipe can be easily installed. 
(6)  Install the unit where the drain pipe can be easily installed.
(7)  Install the unit where noise and vibrations are not ampli

fi

 ed. 

(8)  Take servicing, etc., into consideration and leave the spaces. Also install the unit 

where the 

fi

 lter can be removed.

(9)  Do not install the unit where it will be exposed to direct sunlight.

9367702107-02_IM.indb   Sec1:2

9367702107-02_IM.indb   Sec1:2

1/25/2013   3:51:34 PM

1/25/2013   3:51:34 PM

Summary of Contents for ABHA30GATH

Page 1: ...TÉRIEURE type plafonnier UNIDAD INTERIOR tipo techo Pour le personnel agréé uniquement Únicamente para personal de servicio autorizado MANUALE DI INSTALLAZIONE UNITÀ INTERNA tipo a soffitto A uso esclusivo del personale tecnico autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπος οροφής Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό MANUAL DE INSTALAÇÃO UNIDADE INTERIOR Tipo de tecto Apenas para...

Page 2: ...e parts Always consult authorized service personnel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 1 2 1 Precautions for using R410A refrigerant WARNING Do not introduce any substance other than the prescribed refrigerant into the refrigeration cycle If air enters the refrigeration cycle the pressure in the refrigeration ...

Page 3: ...door unit in the following areas Area with high salt content such as at the seaside It will deteriorate metal parts causing the parts to fail or the unit to leak water Area filled with mineral oil or containing a large amount of splashed oil or steam such as a kitchen It will deteriorate plastic parts causing the parts to fail or the unit to leak water Area that generates substances that adversely...

Page 4: ...sh air intake refer to 8 FRESH AIR INTAKE Side cover B Right side Air filter Intake grille Tapping screw INDOOR UNIT Side cover B Left side Side cover A Right side 3 3 2 Indoor unit installation You can use the accessory template to help you install the indoor unit The template helps you determine the appropriate locations for suspension bolts and pipe openings drain pipe and connection cable Dril...

Page 5: ...hat have clean external and internal sides without any contamination which may cause trouble during use such as sulfur oxide dust cutting waste oil or water For 4 Left rear piping 5 Left piping Transfer the Drain cap and Drain cap seal Drain cap seal Drain cap Indoor unit Drain pan Drain cap seal Drain cap Push cap all the way on as far as it will go knockout hole for drain hose Indoor unit CAUTIO...

Page 6: ...er a prolonged period causing refrigerant to leak and generate a hazardous gas if the refrigerant comes into contact with a flame 4 3 1 Flaring Use special flare tool exclusive for R410A 1 Cut the connection pipe to the necessary length with a pipe cutter 2 Hold the pipe downward so that cuttings will not enter the pipe and remove any burrs 3 Insert the flare nut always use the flare nut attached ...

Page 7: ...it pipe Body side Tighten with 2 wrenches Holding wrench Flare nut Flare nut mm in Tightening torque N m kgf cm 6 35 1 4 dia 16 to 18 160 to 180 9 52 3 8 dia 32 to 42 320 to 420 12 70 1 2 dia 49 to 61 490 to 610 15 88 5 8 dia 63 to 75 630 to 750 19 05 3 4 dia 90 to 110 900 to 1 100 CAUTION Be sure to install the pipe against the port on the indoor unit and the outdoor unit correctly If the centeri...

Page 8: ...on cables and power cables or ones specified by the manufacturer Improper connections insufficient insulation or exceeding the allowable current can cause electric shock or fire For wiring use the prescribed type of cables connect them securely making sure that there are no external forces of the cables applied to the terminal connections Improperly connected or secured cables can cause serious ac...

Page 9: ...and indoor units does not exceed the 15 A For RB unit MCA refer to the RB unit installation manual If the capacity of connected RB units and indoor units exceeds the upper limit either add breakers or use a breaker with a greater capacity B Earth leakage breaker requirements Breaker capacity Maximum connectable indoor units or indoor units RB units 30 mA 0 1 sec or less 44 or less 100 mA 0 1 sec o...

Page 10: ...ighten the terminal screws to the specified torques otherwise abnormal overheating may be produced and possibly cause heavy damage inside the unit Tightening torque M4 screw Power supply L N GND 1 2 to 1 8 N m 12 to 18 kgf cm 6 3 2 Transmission and Remote controller cable Shielded cable no film 30 mm 40 mm Remote controller cable 30 mm Y1 Y2 Y3 40 mm For 3 wire type 30 mm For 2 wire type Connect r...

Page 11: ...he Apply voltage terminal CNA01 CNA03 Input device 1 Input device 2 Input device 3 Load resistance Load resistance Load resistance 1 DC power supply 12 to 24V connected unit a a a P C B CNA01 CNA03 b 1 Make the power supply DC12 to 24V Select a power supply capacity with an ample surplus for the connected load Do not impress a voltage exceeding 24V across pins 1 2 and 1 3 a The allowable current i...

Page 12: ...ch indoor unit within the group Selection method of functions Operation Stop mode or Emergency stop mode Forced stop mode can be selected with function setting of indoor unit Forced thermostat off function Edge input only Connector Input signal Command Ch3 of CNA03 or CNA04 OFF ON Thermostat off ON OFF Normal 2 External output A twisted pair cable 22AWG should be used Maximum length of cable is 25...

Page 13: ...N Use an insulated screwdriver to set the DIP switches Rotary switch Example 0 Rotary switch Example 0 Setting Setting range Type of switch Indoor unit address 0 to 63 Setting example 2 IU AD 10 IU AD 1 Refrigerant circuit address 0 to 99 Setting example 63 REF AD 10 REF AD 1 1 Indoor unit address Rotary switch IU AD 1 Factory setting 0 Rotary switch IU AD 10 Factory setting 0 When connecting mult...

Page 14: ... Service tool Web monitoring tool DIP switch setting Set the DIP switch SET 4 SW3 referring to the Table C DIP switch SET4 OFF ON SW SW SW SW 1 2 3 4 Table C DIP switch SET 4 SW3 Cooling temperature setting range OFF Factory setting Standard 18 to 30 C ON Extension 18 to 32 C NOTE Please do not make a standard setup and an extension setup intermingled in remote controller group FUNCTION SETTI 1 7 ...

Page 15: ...sary 01 Stop 7 4 1 Button name and function TIMER indicator lamp Orange MANUAL AUTO button OPERATION indicator lamp Green FILTER indicator lamp Red 7 4 2 Checking the function settings Press and hold the MANUAL AUTO button on the indoor unit for 3 seconds to check the function settings It is necessary to disconnect the power in order to return to normal operation mode 1 Indoor unit and refrigerant...

Page 16: ...alf concealed orientation only install side cover A 7 Install the air filters 10 TEST RUN 1 10 1 Test run using Outdoor unit PCB Refer to the Installation Manual for the outdoor unit if the PCB for the outdoor unit is to be used for the test run 10 2 Test run using remote controller Refer to the Installation Manual for the remote controller to perform the test run using the remote controller When ...

Page 17: ...Indoor unit power supply abnormal 3 2 Indoor unit main PCB error 3 10 Indoor unit communication circuit wired remote controller error 4 1 Indoor unit room temp thermistor error 4 2 Indoor unit heat ex temp thermistor error 5 1 Indoor unit fan motor 1 error 5 2 Indoor unit coil expansion valve error 5 3 Indoor unit water drain abnormal 9 15 Outdoor unit miscellaneous error 13 1 RB unit error Displa...

Reviews: