Air4Gp Installation Guide
Page 37
Commercial in Confidence
UGD-D00236 Rev B
7.2 DC Power Connection
Insert the DC cable through the gland cover and O-ring, Strip back 100mm outer sheath. Strip
back 5mm from both inner cores. Solder-Tin the inner cores to stop fray when inserting into
terminal block. Insert the DC cable and screw to terminal block J3, adhering to polarity indicated.
Lay the cable around (not over) J1.
7.3 PoE Connection
Strip back 60mm of the outdoor CAT5e sheath. Insert the CAT5e pairs through the glands.
Punch-down the CAT5e cable-pairs to the IDC connectors using the punch-down-tool, being
careful to conform to the coloring scheme. The Punch-down tool is polarised, so use the cutting
scissors of the Tool to the
LEFT
side of the picture. Shake out all the loose cuttings.
7.4 Network Connection
Strip back 60mm of the outdoor CAT5e sheath. Insert the CAT5e pairs through the glands.
Punch-down the CAT5e cable-pairs to the IDC connectors, being careful to conform to the
coloring scheme. The Punch-down tool is polarised, so use the cutting scissors of the Tool to the
RIGHT
side of the picture.
Do not mix CAT6 for the network and CAT5e for POE, generally stick to all CAT5e or all CAT6.
7.4.1 Shielded Cables
It is preferred to use shielded cable. Connect the two drain wires through a cable sheath and ring
crimp them to the alternate earth screw (bottom right).
7.4.2 Attachment
Attach the box using 2 off #6 1” Pan-Pozi Self Tapping screws.
7.4.3 Waterproofing
Tighten all glands for IP66 seal. Use two spanner wrenches to prevent the barrel rotating. Do not
over-tighten the barrel to lock-nut which would have been tightened by the factory.
Tighten the Lid for IP66 seal.
7.4.4 AC/DC PSU Attachment
Attach the power supply using 4
off #6 0.5” Pan-Pozi Self Tapping screws.