Trouble Shooting 

Trouble 

Check & Remedy

The machine cannot be   ·Confirm that the power cord is correctly
operated

connected with the outlet.

After operating, 

·Due to an over electric current, the power 

the power turns off.           source is being cut.  

Please check the circuit breaker.

Inhaling/ exhaling is weak. ·Check if the filter is damaged or contaminated.

Dust is flowed out of       ·Check if the filter is damaged or correctly installed. 
the exhaling hole.

Filter

DO NOT OPERATE THE AIRREX WITHOUT THE HEPA FILTER INSTALLED!
OPERATING WITHOUT THE HEPA FILTER INSTALLED OR USING NON-APPROVED
POWER CORDS MAY CAUSE DAMAGE TO THE ELECTRICAL SYSTEM OR 
MECHANICAL COMPONENTS. FAILURE TO COMPLY WILL VOID ALL WARRANTIES.

1. Size : 27.5 X 25.3 X 0.6 (inch)
2. The filter can collect dust of 10~30㎛ up

to 20~85% in accordance with 
the standard of weight method 

PRE-FILTER

1. Size : 24.0 X 24.0 X 0.8 (inch)
2. Aluminum frame is put around 

the outer edge. It can collect dust of 
10~20㎛ up to 90% in accordance with 
the standard of weight method.

PRE-FILTER PANEL

Summary of Contents for HSC-HEPA2000

Page 1: ...efully before use and follow them at all times This Machine is specified for use on a 115V 60Hz single phase power supply You must check that the local electricity supply is the same and have the appropriate plug fitted by a qualified electrician The Warranty form is on Page 8 Please complete it now and keep in a safe place We have a policy of continual improving to our products The contents featu...

Page 2: ...2 TABLE OF CONTENTS Safety Instructions Specifications Wiring diagram Controller Trouble Shooting Filter Change of filter Warranty 3 4 4 4 5 5 6 8 ...

Page 3: ...anger of explosion Remove any obstacle at the inhaling hole and the exhaling hole When cleaning the surface of the product pull the power cord out and use soft cloth for preventing a scratch Do not use wet cloth wax or thinner Do not put a hand or foreign substance into the inhaling hole or the exhaling hole It may occur a malfunction to the product or a physical injury Keep this manual in a visib...

Page 4: ...essure Gauge 2 Pressur Sensing Port 3 Circuit Breaker 4 High Off Low Switch 1 Before connecting the power cord confirm the switch is turned off without fail 2 For starting the product press the switch in the control panel to the low or high 3 For stopping the operation press the OFF ...

Page 5: ...ly installed the exhaling hole Filter DO NOT OPERATE THE AIRREX WITHOUT THE HEPA FILTER INSTALLED OPERATING WITHOUT THE HEPA FILTER INSTALLED OR USING NON APPROVED POWER CORDS MAY CAUSE DAMAGE TO THE ELECTRICAL SYSTEM OR MECHANICAL COMPONENTS FAILURE TO COMPLY WILL VOID ALL WARRANTIES 1 Size 27 5 X 25 3 X 0 6 inch 2 The filter can collect dust of 10 30 up to 20 85 in accordance with the standard o...

Page 6: ...s due to a clogging in the filter Time of filter change As the asbestos dust attached to the filter may be scattered do work in a closed space wearing a protective gear Cut the main power then do work The removed filter after change must put in a doubled vinyl pack then discard it legally Cautions for filter change How to change filter 1 1 After opening the door pull out the reinforced staffs 1 2 ...

Page 7: ... tool as the picture pull off the bracket fixing the filter 2 3 Change the contaminated or damaged pre filter panel and hepa filter in order Fix the new filter in reverse order 2 1 2 3 MEMO 2 2 2 Pre Filter Panel Hepa Filter change Change of filter ...

Page 8: ... abuse or damage then all repairs will be charged for 3 This warranty applies to your country 4 Proof and date of purchase must be supplied 5 Please complete the details below and keep this warranty in a safe place 6 All transport charges back to the dealer are at the customers cost Keep all original packaging to facilitate return Return to customer will be at dealers cost if genuine warranty clai...

Reviews: