STRUCTURE & DESCRIPTION

 STRUCTURE & DESCRIPTION FOR MODEL

Exhaust Duct

Heating 

Tube

Safety Grille

Back Reflection

Oil tank

Side

Reflection

Bottom

Reflection

Power code

(a.c. 220/230V only)

Control Panel

CONTROLLER

TILT

LOCK

LOCK

Cur Temp

Set Temp / Time

FUEL

EMPTY

MISFIRE

OVERHEAT

1. LED DISPLAY

    It displays the status of temperature, time, 

    operation, and error, etc.

2. TEMPERATURE CONTROL MODE

    It is lighten at the temperature control mode.

3. TIME CONTROL MODE

    It is lighten at the time control mode.

4. 

IR RECEIVER FOR REMOTE CONTROLLER

5. ON / OFF 

    Run and stop button

6. TEMP/TIME SELECTION BUTTON

    To select temperature or time control mode.

7. UP/DOWN

    To set or change the temperature or time.

8. LOCK

 

 If you push this lock button for 3sec, 

    the controller is locked. And if you push 

    again for 3sec. this fuction is released. 

9.  OFF TIMER 

    

To select whether off timer mode is 

     operated or not.

10. OFF TIMER LED 

     

To show whether off timer mode is 

      operating.     

11. MISFIRE 

     

It shows the misfire on the burner.

 

12. OPERATION LAMP   

     

It is lighten on operation.

13. FUEL GAUGE DISPLAY 

     

It displays fuel remain in 3 steps. 

14. OVERHEATING  

     

It shows overheating status if the 

     temperature goes up to 105

.

15 TILT SENSOR 

     

It is turned on in case of inclination 

     over 30deg. or an excessive motion

     is detected.

 

16. LACK OF FUEL  

      It shows the remaining fuel amount.

17. LOCK LED

   

When the machine is in the lock

   mode, the LED of this LOCK is 

   lighten.

overheating 

sensor

(Automatic

Recovery)

Electronic 

fuel pump

Fuel inlet

Fuel tank

Air suction 

hole

Igniter

Tilt sensor

Fuel gauge

burner

Flame 

sensor(CdS)

Fuel filter

Control

panel

Summary of Contents for AH-300

Page 1: ...nd easily It is obligatory that the user read Notice for Safety carefully before using and should be aware of this notice whenever using this heater This heater is designed for your country only If yo...

Page 2: ...MOTE CONTROLLER REPLACING BATTERIES IN REMOTE CONTROLLER HOW TO USE OPERATION STOP TEMPERATURE CONTROL TIME CONTROL SELF DIAGNOSIS FOR THE SAFETY DEVICE CLEANING MAINTENANCE DAILY CHECK POINTS ADJUSTM...

Page 3: ...ug from the outlet wait until the heated furnace is cooled down sufficiently Otherwise it may cause an electric shock or a burn Do not place or use any inflammable near the heater including fuel gas t...

Page 4: ...s exposed to fire or burn It is dangerous to use this heater for a long time in the closed room or in case there are children or the old and the weak It is recommended that the user open the windows t...

Page 5: ...r you fix the installation lock the caster for avoiding unexpected movement Do not use this heater near fabri curtain carpet or plastic or vinyl curtain which may cover th heater in case of falling do...

Page 6: ...K If you push this lock button for 3sec the controller is locked And if you push again for 3sec this fuction is released 9 OFF TIMER To select whether off timer mode is operated or not 10 OFF TIMER LE...

Page 7: ...ated 3 Close cover push until cover click Point remote control at machine receiver Remote control will not function where strong lights such as 3 florescent neon or strong sunlight interferes In this...

Page 8: ...returned to the oil tank For 10sec from the time of burner off the solenoid valve is operation which makes remaining oil returned to the oil tank and by this device the smell caused by unburned gas ar...

Page 9: ...RE OVERHEAT TILT LOCK LOCK Cur Temp Set Temp Time FUEL EMPTY MISSFIRE OVERHEAT TILT LOCK LOCK Cur Temp Set Temp Time FUEL EMPTY MISSFIRE OVERHEAT TILT LOCK LOCK Cur Temp Set Temp Time FUEL EMPTY MISFI...

Page 10: ...splayed blinking time is set as Repetition time At that time the former Repetition time is automatically erased 4 At the opertion mode the opartion simbol and repetition time both are displaed and whe...

Page 11: ...is ON post fuggy is worked and all other operation is stop 4 LACK OF FUEL LAMP DISPLAY OIL If continuing operation even after display of the oil shortage and amount of oil is reached to the below lim...

Page 12: ...eater and pull out the plug as the above picture and clean according to the following instruction Please pull out the front grille by raising it and pull it out to the front Please clean the heating r...

Page 13: ...xed correctly Mark A should be inserted fully CHANGE OF COMPONENTS In case you need to change components please contact us In case repair or exchange of components please contact the service center op...

Page 14: ...nd not distribute oil If oil is all consumed without remaining in the tank air can be flow into inside electric pump The method to flow out air Operate the heater When the electric pump operated turn...

Page 15: ...for a while Refer to page 16 Inclination display Ground surface is inclined Replace the heater in plain ground lamp ON or not plain Refer to page 16 Can you see Er2 Error on Temperature Select Timer...

Page 16: ...the air in the electric pump pump and nozzle Check if the fuel is It may cause less Drain the existing fuel and fill with Diesel or kerosene performance trouble Diesel or kerosene only Water or any ot...

Page 17: ...ump pressurized spray type POWER SUPPLY a c 220 230V 50Hz Single Phase ELECTRIC POWER CONSUMPTION 80W 80W 80W 80W FUEL TANK SIZE 45 45 70 70 PRODUCT SIZE W x D x H WEIGHT 41 kg 48 kg 60 kg 65 kg SAFET...

Page 18: ...r you free repair service under our warranty clause 1 Warranty period is 12 months after purchasing date If the problem is occurred by the mistake or misuse of the customer we charge a repair cost eve...

Page 19: ...19 memo...

Page 20: ...Nordic Oy Juan dong 86 Gilpa ro 71beon gil Nam gu Incheon Korea TEL 82 32 509 5834 FAX 82 32 502 5519 E mail sales airrex co kr Website www airrex biz Fl tbackantie 1 04150 Martinkyl Finland E mail in...

Reviews: