7.0 POSSIBILIBIES OF FAILURE
1 Compressor does not run at starting pressure:
*
blown fuse
- renew the fuse
*
tank at pressure
- discharge
*
motor broken
- repair/renew
*
defective pressure switch
- repair/renew
2 Repeating thermal failure:
*
blown fuse
- renew fuse
*
loose wire
- repair
*
pressure switch does not releave
- repair/renew valve
air circuit
*
too low voltage
- remove extension cable or use heavier
*
overloading
- reduce loading
3 Compressor keeps blowing off air:
*
defective non-return valve
- repair/renew
4 Too little air production:
*
dirty air filter
- clean/renew filter
*
defective valves
- renew
* draintap condensation water is open
- close the draintap
5 Leaking safety valve:
*
pressure too high
- set pressure switch
*
defective safety valve
- renew
8.0 TECHNICAL DETAILS
Type
HL 360/50 compact
Order number
36852
Number of cylinders/stages
1/1
Motorpower
2,5 Hp/1,8 kW
Volt
230 V/50 Hz
Air tank
50 litres
Oil tank
0,8 litres
Operating pressure
6 bar
Maximum pressure
8 bar
Sound pressure level
78 dB(A)/7 m
Air intake capacity
360 l/min.
Protected with
16 amp.
Service
30% per 60 minutes
Weight
38 kg
Dimensions (lxwxh)
480x410x1050 mm
Modelchanges reserved.
All compressors are provided with Euro-Norm (CE-Choice)