5. Troubleshooting - Fountain
6. Troubleshooting - LED Lights
IF FOUNTAIN WON’T RUN
ISSUE
CORRECTION
GFCI Tripped
Reset GFCI
Power Cord Cut
Repair or replace power cord
Intake plugged
Clean intake
Timer not running
Verify timer is keeping time, replace timer if not
Timer not set to AUTO
Press MANUAL button to move indicator to AUTO
Not enough water in reservoir
Bring water level up to at least 24” at fountain
Fountain impeller stuck
Remove fountain, clean replace impeller
Breaker tripped due to overcurrent
Reduce current load on circuit, check other equipment
Breaker tripped to GFCI
Check power cord for cuts, replace/repair
IF NOZZLE HAS POOR QUALITY STREAMS
ISSUE
CORRECTION
Intake plugged
Clean intake
Not enough water in reservoir
Bring water level up to at least 24” at fountain
Debris caught in nozzle hole
Remove nozzle, clean, replace
Water coming over the float
Check fountain float for water, replace if any
IF FOUNTAIN STARTS AND STOPS
ISSUE
CORRECTION
Intake plugged
Clean intake
Not enough water in reservoir
Bring water level up to at least 24” at fountain
IF STREAMS RAISE AND LOWER
ISSUE
CORRECTION
Not enough water in reservoir
Bring water level up to at least 24” at fountain
Water coming over the float
Check fountain float for water, replace if any
IF FOUNTAIN HUMMING - RUNNING
ISSUE
CORRECTION
Normal running
Nothing
IF FOUNTAIN HUMMING - NOT RUNNING
ISSUE
CORRECTION
Intake plugged
Clean intake
Voltage not high enough for starting
Make sure voltage at receptacle is 120V+-5%
Fountain impeller stuck
Remove fountain, clean replace impeller
Locked rotor
Clean rotor with a scrub brush
IF LIGHTS TURN ON AND OFF INTERMITTENTLY
ISSUE
CORRECTION
Water in fixtures
Contact Airmax or local dealer for repair/replacement
LED bulb driver failed
Contact Airmax or local dealer for repair/replacement
IF LIGHTS DIM
ISSUE
CORRECTION
Voltage not high enough for starting
Make sure voltage at receptacle is 120V+-5%
Lens might be dirty
Clean with a non-abrasive brush or cleaner
IF ONE OR MORE (NOT ALL) LIGHTS DIM
ISSUE
CORRECTION
Water in fixtures
Contact Airmax or local dealer for repair/replacement
LED bulb driver failed
Contact Airmax or local dealer for repair/replacement
IF ALL LIGHTS OFF
ISSUE
CORRECTION
GFCI Tripped
Reset GFCI
Power Cord Cut
Repair or replace power cord
Water in fixtures
Contact Airmax or local dealer for repair/replacement
Voltage not high enough for starting
Make sure voltage at receptacle is 120V+-5%
Timer not running
Verify timer is keeping time, replace timer if not
Timer not set to AUTO
Press MANUAL button to move indicator to AUTO
IF ONE OR MORE (NOT ALL) LIGHTS OFF
ISSUE
CORRECTION
Water in fixtures
Contact Airmax or local dealer for repair/replacement
LED bulb driver failed
LED Bulb failed
IF LIGHTS FLICKER
ISSUE
CORRECTION
Water in fixtures
Contact Airmax or local dealer for repair/replacement
Voltage not high enough for starting
Make sure voltage at receptacle is 120V+-5%
LED bulb driver failed
Contact Airmax or local dealer for repair/replacement
ENGLISH