![AirMan SDG1 00S-6A6 Instruction Manual Download Page 41](http://html1.mh-extra.com/html/airman/sdg1-00s-6a6/sdg1-00s-6a6_instruction-manual_2878215041.webp)
4 .. Operation
4. 7 Emergency Stop
A
CAUTION
1------------------,
• The Emergency Stop button should be used only for emergency stop.
• Regularly check the operating performance.
• If it is necessary to stop the generator for emergency,
press the Emergency Stop button.
• To reset the button, turn the button head in the
direction of the arrow. If it is not reset, the machine
cannot restart to operate.
4.8 Air Bleeding
Emergency stop
..
Emergency stop button
(Push-button)
A040192
Reset
H980179
Should the machine stop due to the shortage of fuel, perform the air bleeding operation according to
the following procedures.
(Procedure)
CD Replenish fuel.
@ Place the operation selector switch to the "MANUAL" position.
@ Turning the starter switch to "RUN'' position, the electromagnet pump functions to bleed the air in
fuel pipe system automatically.
@ The air bleeding operation can be finished within 20 to 30 seconds.
4-13