background image

- - 6 - - 

 

REMOTE CONTROL 

1

Button instruction 

                                                                         

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode 

When unit is on or 

under Timer 

Mode, 

press this key to choose 

cooling, 

heating, 

dehumidifying or fan 

Fan   

Press this to choose  fan 

speed (low, middle or 

high).  When  the unit is 

turned on at first time, 

the default speed is low   

 

Temperature Button 

Press this button to 

choose 

  Centigrade 

or 

  Fahrenheit 

Timer 

Press this to set auto on 

time when the unit is 

off, to set auto off time 

when the unit is on. 

Press

to set the auto 

on/off time you want.   

 

Up/Down 

Press

temperature will 

increase 

1

or1

℉ ,

press

  temperature 

will decrease

 

1

or 1

℉。

Or adjust time under 

timer Mode 

Power Button 

Press this  button to 
turn on/off the unit. 

Swing Button 

Press this button to 

control swing function. 

Econ Button 

Under cooling model, 

press this button to get 

energy saving mode, Low 

wind, and low noise. 

Room temperature display 

Press this to display  the 

room  temperature, press it 

again 

to cancel room 

temperature  display;  it can 

be used as a  thermometer 

when the unit is off 

 

Summary of Contents for YPH-12H-S1

Page 1: ...or selecting super quality air conditioner Please be sure to read this manual carefully before using it Any question please contact the professional for help USER MANUAL PORTABLE AIR CONDITIONER Model...

Page 2: ...1 IMPORTANT SAFEGUARD 2 FEATURES AND PARTS LIST 3 CONTROL PANEL 4 REMOTE CONTROL 6 OPERATION METHODS 8 INSTALLATION 10 WATER DRAINAGE METHODS 13 MAINTENANCE 14 TROUBLE SHOOTING 15 INSTALLATION ACCESS...

Page 3: ...ng room Do not let children play by himself or herself Children and deformity suffer cannot use the conditioner without guardian Never use the main plug as a switch to start and stop the air condition...

Page 4: ...al protecting Low noise and strong wind Auto swing makes wind blow from left to right automatically Three minute restart delay to protect compressor Parts list 1 Control panel 2 Horizontal louver 3 Ve...

Page 5: ...Celsius to Fahrenheit or vice versa Swing press this button to make the vertical louver swing automatically Press it again the swing will stop Speed Press this button to select high middle or low fan...

Page 6: ...nder fan mode TEMP means temperature means centigrade and means Fahrenheit When 88 is E2 it means room temperature sensor faulty When 88 is E3 evaporator sensor faulty When 88 is df the cooling system...

Page 7: ...off to set auto off time when the unit is on Press to set the auto on off time you want Up Down Press temperature will increase 1 or1 press temperature will decrease 1 or 1 Or adjust time under timer...

Page 8: ...ault is on 5 Fan It is available when the unit is cooling or fan Mode you can set fan speed as you need 6 Room temperature and set temperature When the unit is off it displays room temperature and the...

Page 9: ...n when the unit is off Same as timer off set After time is set you may choose working mode if choose cooling or heating mode you can set temperature if choose dehumidifying mode you can set targeting...

Page 10: ...mode the LCD will display Select the fan speed by pressing SPEED button on the remote Under this mode if press SPEED button for 5 seconds inner dehumidifying mode will be activated which means both u...

Page 11: ...6 2 Put the other end discharge to the nearest window Leave at least 50cm place around it NOTE The length of the air exhaust duct is about 170cm when it s extended adapters included and 60cm when not...

Page 12: ...y in some aspects of the installation procedures for certain types of windows Please refer to the illustrations Fig 7 and Fig 8 4 Mounting illustrations 1 Mounting in the wall Fig 7 Fig 8 Vertical Hor...

Page 13: ...12 2 Correct bending 3 Wrong bending 45 Fig 10 Fig 12 45 Fig 11...

Page 14: ...water is full the water full indicator will light and the compressor will stop working The buzzer will buzz 10 times every 5 minutes until the water is below the high level or drained by hand When the...

Page 15: ...ter and dry it in a shaded place 2 Push the air filter back into the original position End of season 1 Pull the plug out of the drain mouth and remove the water from the water plate and inner water ta...

Page 16: ...table Is fan speed set at low Clear off the blocks Move the heat source Clean the air filter Change temperature Select suitable fan speed Noisy Vibration It is the inner refrigerant flowing inside Is...

Page 17: ...xible exhaust hose with adapters 1 set Stretch from 28cm up to 150cm Square connector 1 pc Flat and round connector 1 pc Adjustable window slider kit 1 set Stretch from 90cm 130cm Screw the length is...

Page 18: ...17 APPENDIX Fuse Parameter Type FSD Voltage 250V Current 3 15A Disposal Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary...

Reviews: