- 14 -
USE AND MAINTENANCE
•
It is recommended to operate the appliance prior to
cooking.
It is recommended to leave the appliance in operation for
15 minutes after cooking is terminated in order to com-
pletely eliminate cooking vapours and odours.
The proper function of the cooker hood is conditioned by
the regularity of the maintenance operations, in particu-
lar, the active carbon filter.
•
The anti-grease filters capture the grease particles
suspended in the air, and are therefore subject to clog-
ging according to the frequency of the use of the appli-
ance.
In order to prevent fire hazard, it is recommendable to
clean the filter at a maximum of 2 months by carrying out
the following instructions:
- Remove the filters from the cooker hood and wash them
in a solution of water and neutral liquid detergent, leaving
to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several
washes. This is not cause for customer complaint nor
replacement of panels.
•
The active carbon filters purify the air that is replaced
in the environment. The filters are not washable nor re-
useable and must be replaced at maximum every four
months. The saturation of the active carbon filter de-
pends on the frequency of use of the appliance, by the
type of cooking and the regularity of cleaning the anti-
grease filters.
•
Clean the fan and other surfaces of the cooker hood
regularly using a cloth moistened with denatured alcohol
or non abrasive liquid detergent.
• The illumination installation is designed for use during
cooking and not for prolonged general illumination of the
environment. Prolonged use of the illumination installa-
tion notably reduces the duration of the bulb.
COMMANDS:
(Fig.11)
Push-button A
= on/off lights switch
Push-button B
= on/off cooker hood switch. The appli-
ance switches on at speed level 1, If the cooker hood is
on depress the push-button for ½ a second to switch off
the cooker hood. If the cooker hood is at speed level 1
it will not be necessary to depress the push-button to
switch the cooker hood off. Decreases the motor speed.
Display C
= indicates the motor speed level selected and
activates the timer.
Push-button D
= switches on the cooker hood. Increases
the motor speed. Touching the key at 3rd speed, the
intensive function runs for 10', then the appliance go
back to work at the original speed. During this function
the display blinks.
Push-button E
= Timer, when active should be visible via
the decimal point flashing in the Display “C”. Depressing
the push-button when the cooker hood is in the off mode
will switch on the appliance at the first speed level for 15’
[minutes]. The Timer switches the cooker hood off com-
pletely (lamps and motor) after 15’ [minutes].
E.g.: if the lamps only switch on, and the timer switch is
depressed then the lamp will turn off after 15’ [minutes].
To deactivate the timer depress the push-button a sec-
ond time (twice).
The "Automatic stop timer" delays stopping of the hood,
which will continue functioning for 15 minutes at the
operating speed set at the time this function is activated.
• CONTROLS: ELECTRONIC
(fig.10)
A
= LIGHT
B
= OFF/SPEED I
C
= SPEED II
D
= SPEED III
E
= AUTOMATIC STOP TIMER – 15 minutes
F
= FILTER SATURATION RESET LIGHT
When the “filter saturation” light flashes, the anti-grease
filters must be washed.
When the light comes on without flashing, the anti-grease
filters must be washed and the carbon filters replaced (in
case of operation whit the recycling version).
When this operation has been completed, press the key
to reset it.
• COMMANDS:
(Fig.9A) LUMINOUS the key symbols are
explained below:
A
= LIGHT
B
= OFF
C
= SPEED I
D
= SPEED II
E
= SPEED III
F
= AUTOMATIC STOP TIMER - 15 minutes
•
If your appliance does have the
INTENSIVE
speed
function, press key E for two seconds and it will be
activated for 10 minutes after which it will return to the
previously set speed.
When the function is active the LED flashes. To inter-
rupt it before the 10 minutes have expired press key
E
again.
•
By pressing key
F
for two seconds (with the hood
switched off) the “
clean air
” function is activated. This
function switches the appliance on for ten minutes every
hour at the first speed. As soon as this function is acti-
vated the motor starts up at the first speed for ten
minutes, During this time key
F
and key
C
must flash at
the same time.
After ten minutes the motor switches off and the LED of
key
F
remains switched on with a fixed light until the
motor starts up again at the first speed after fifty min-
utes and keys
F
and
C
start to flash again for ten minutes
and so on.
By pressing any key for the exclusion of the hood light
the hood will return immediately to its normal functioning
(e.g. if key D is pressed the “
clean air
” function is deac-
tivated and the motor moves to the 2nd speed straight
away. By pressing key
B
the function is deactivated).
• The “automatic stop timer” delays stopping of the
hood, which will continue functioning for 15 minutes at
the operating speed set at the time this function is
activated.
• COMMANDS:
(Fig.9 B)MECHANICAL_ the key symbols
are explained below:
A
= LIGHT
B
= OFF
C
= SPEED I
D
= SPEED II
E
= SPEED III
G
= MOTOR WORKING indicator
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR EVENTUAL DAMAGES CAUSED BY BREACHING
THE ABOVE WARNINGS.