External Modem User's Manual
40
CONNECT 115200
24
x x x x
Connection established at 115200 bps
CONNECT 1200TX/75RX
25
x x x x
V.23 established:transmit at 75 bps, receive at
1200 bps
CONNECT 75TX/1200RX
26
x x x x
V.23 established:transmit at 1200 bps, receive
at 75 bps
CONNECT BELL 300
28
x x x x
Connection established at Bell 300 bps
CONNECT V21
29
x x x x
Connection established at V.21 300 bps
( Display DCE speeds by ATW0 and ATW2 )
CONNECT 16800
15
x x x x
Connection established at 16800 bps
CONNECT 19200
16
x x x x
Connection established at 19200 bps
CONNECT 21600
17
x x x x
Connection established at 21600 bps
CONNECT 24000
21
x x x x
Connection established at 24000 bps
CONNECT 26400
30
x x x x
Connection established at 26400 bps
CONNECT 28800
31
x x x x
Connection established at 28800 bps
CONNECT 31200
32
x x x x
Connection established at 31200 bps
CONNECT 33600
33
x x x x
Connection established at 33600 bps
(V.90 mode)
CONNECT 28000
34
x x x x
Connection established at 28000 bps
CONNECT 29333
35
x x x x
Connection established at 29333 bps
CONNECT 30666
36
x x x x
Connection established at 30666 bps
CONNECT 32000
37
x x x x
Connection established at 32000 bps
CONNECT 33333
38 x x x x
Connection established at 33333 bps
CONNECT 34666
39 x x x x
Connection established at 34666 bps
CONNECT 36000
40 x x x x
Connection established at 36000 bps
CONNECT 37333
41 x x x x
Connection established at 37333 bps
CONNECT 38666
42 x x x x
Connection established at 38666 bps
CONNECT 40000
43 x x x x
Connection established at 40000 bps
CONNECT 41333
44 x x x x
Connection established at 41333 bps
CONNECT 42666
45 x x x x
Connection established at 42666 bps
CONNECT 44000
46 x x x x
Connection established at 44000 bps
CONNECT 45333
47
x x x x
Connection established at 45333 bps
CONNECT 46666
48
x x x x
Connection established at 46666 bps
CONNECT 48000
49
x x x x
Connection established at 48000 bps
CONNECT 49333
50
x x x x
Connection established at 49333 bps
CONNECT 50666
51
x x x x
Connection established at 50666 bps
CONNECT 52000
52
x x x x
Connection established at 52000 bps
CONNECT 53333
53
x x x x
Connection established at 53333 bps
CONNECT 54666
54
x x x x
Connection established at 54666 bps
CONNECT 56000
55
x x x x
Connection established at 56000 bps
6.3 Application Examples
6.3.1 Dialing a Remote Modem
Command line: ATDP9WT002, (886)-7128423<CR>
This command line instruct the modem to dial a remote modem through a PBX. The modem
first use pulse dialing to dial 9 (the access code of the PBX), wait for outside dial tone, and
then use touch tone dialing to dial 002 once a one-second continuous dial tone is detected
within 30 seconds, pause for 2 seconds (if S8=2) and then dial 8867128423.
6.3.2 Dialing a Stored Number
Command line: AT&Z2=T03,709394<CR>
Command line:
ATDS=2<CR>
The first command line store the dial string T03, 709394 to the 3rd location in NVRAM.
Afterwards you can use the second command line to dial this stored number. The dial string
T03, 709394 will appear on the screen to indicate the number being dialed.