Operation
8
3A4133B
Operation
Spray
1.
Disengage trigger lock.
2.
Be sure the arrow shaped tip faces for-
ward (spray).
3.
Hold gun perpendicular and approxi-
mately 12-inches (30 cm) from surface.
Move gun first, then pull gun trigger to
spray a test pattern.
4.
Slowly increase pump pressure until
coverage is uniform and even (see
sprayer instruction manual for addi-
tional information).
Align Spray
1.
2.
Loosen tip guard retaining nut.
3.
Align tip guard horizontally to spray a
horizontal pattern.
4.
Align tip guard vertically to spray a ver-
tical pattern.
5.
Tighten tip guard retaining nut.
Clear Tip Clog
In the event that particles or debris clog the
spray tip, this sprayer is designed with a
reversible spray tip that quickly and easily
clears the particles without disassembling the
sprayer.
1.
Engage trigger lock. Rotate spray tip to
unclog position. Disengage trigger lock.
Trigger gun at waste area to clear clog.
UNCLOG
NOTE:
If spray tip is difficult to rotate when
turning to the unclog position, perform
, page 5, then
turn Prime/Spray valve to spray position and
repeat step 1.
2.
Engage trigger lock. Rotate spray tip
back to spray position. Disengage trig-
ger lock and continue spraying.
SPRAY
ti29569a
HORIZONTAL
VERTICAL
ti29119a
ti29119a
Summary of Contents for Pro-Light 500 17N201
Page 13: ...Notes 3A4133B 13 Notes...
Page 14: ...Notes 14 3A4133B Notes...