Operation
3A0413B
9
Connect Gun to Sprayer
Make sure sprayer is turned off and
unplugged from power source. Refer to your
sprayer instruction manual for priming and
spray instructions.
1.
Attach supply hose to sprayer fluid
outlet.
2.
Attach other end of supply hose to gun
inlet. Use two wrenches to tighten all
connections securely.
3.
Refer to sprayer instruction manual for
priming instructions.
Installing Tip and Tip Guard on Gun
Make certain spray tip and guard are installed
properly.
1.
Perform
Pressure Relief Procedure
,
page 8.
2.
Engage trigger lock.
3.
Verify spray tip and tip guard parts are
assembled in the order shown.
a.
Use spray tip to align gasket and
seal in the tip guard.
b.
Spray tip must be pushed all the
way into the tip guard. Turn spray tip
to push down.
c.
Turn the arrow shaped handle on
the spray tip forward to the spray
position.
4.
Screw spray tip and tip guard assembly
on to the gun and tighten.
To avoid serious injury from skin injection,
do not place your hand in front of the spray
tip when installing or removing the spray
tip.